Product Description

Limited Internal
PRODUCT DESCRIPTION 19 ( 27 )
EAB/SEMCON Staffan Paulusson EN/LZT 720 0491 Uen
EAB/RKW Lena Jonsson Borg 2004-12-28 R1A
Prepared (also subject responsible if other) No
Approved Checked Date Rev Reference
E
Table 7 Cable Gland Capacity
Connection Field Cables
1
See Antenna Connections on page 20
2
7 x 12 mm (diameter) OVP
1 x 15 mm (diameter) GPS
1 x (17 20 mm) (diameter) DC out
3
6 x (1 x 10 mm + 3 x 0.5 mm) (diameter)
4
1 x (17 28 mm) (diameter) AC Connection
Connections on DF
The DF is a modular construction containing seven OVP modules for PCM
links, external alarms, DC out (100 W), and ESB cables.
Optional Configurations in the DF
The table below shows the options that can be used simultaneously through the
OVP modules in the DF. DC out and GPS can always be used independently of
the number of PCM lines, external alarms, and ESB configurations.
Table 8 Optional Configurations in the DF
No. of
PCM
Lines
Used
4 Ext.
Alarms
4 Ext.
Alarms
4 Ext.
Alarms
4 Ext.
Alarms
ESB 1 ESB 2
2
X
(1)
X X X X X
4
X X X O
(2)
X O
6
X X O O O O
8
X O O
O O
(1) Usable with no restrictions or conflicts.
(2) Optional; can be used, but not together with one or more other optional
(O) functions.
Note ESB 1 is always used in the RBS in an ESB chain. ESB 2 is
used only if the RBS is between more RBSs in an ESB chain.
OVP Modules
The capacity of the OVP modules is shown in the table below.