Reference Manual

Environmental Capabilities
Table 7
Environmental Parameters Unit Value
Vibration sinus:
displacement mm 0.6
acceleration m/s² 2
frequency Hz 2-9 9 -200
Vibration random:
ASD m
2
/s
3
0.1
1)
ASD m
2
/s
3
0.2
2)
acceleration m/s² 3.8
1)
acceleration m/s² 5.4
2)
frequency Hz 2-200
Shock:
peak acceleration m/s² 40
3)
duration ms 11
1)
Safe function
2)
Non destruction
3)
This requirement belongs to ’Safe function’ with the exemption:
performance of the RBS shall be verified as ’no loss of calls
Seismic Exposure
The complete equipped RBS shall be tested for seismic exposure.
Deviations shall be reported.
Safe function during seismic exposure. Deviations shall be reported.
Table 8
Test frequency range 1-15 Hz
Required Response Spectrum RRS
Shape of RRS as IEC fig 3
Number of time scale histories 1/ testing direction
Duration of time scale histories 35 s
Number of testing directions 3
If necessary there are possibilities to equip the RBS with an optional
Seismic Exposure protection device.
3.8 Operation Outdoor -33
C - +40
C
This Environmental class corresponds in full to ’Operation Outdoor
-33
C - +45
C’ with the exception of the upper temperature limit.
EN/LZT 720 0008 P2A
2001-11-28
27 (485)
© Ericsson Radio Systems AB
All Rights Reserved
Preliminary