Reference Manual

Operation and Maintenance Terminal
Exception: A DXU which uses the PRACT transmission circuit
does not support the LBO values.
Modify FDL use values for transmission interface.
Sets the individual Facility Data Link (FDL) use values for a T1
transmission interface. The values are defined and referred as
parameter "FDL_use" in the IDB.
Exception: A DXU which uses the PRACT transmission circuit
does not support the FDL_use.
Display FDL use values for transmission interface.
Displays the individual FDL use values for a T1 transmission
interface. The values are defined and stored as parameter
"FDL_use" in the IDB.
Exception: A DXU which uses the PRACT transmission circuit
does not support the FDL_use.
The functions above are normally used at:
Installation (set transmission interface type, set/display available
synchronization source, display/define spare bits, display/switch
on/switch off CRC-4)
Maintenance (monitor maintenance data)
48.3.13 Antenna System
The following user functions, related to the antenna system, are
available in the OMT:
Monitor maintenance data, display any of the following data and
update changes continuously
Diversity
The functions above are normally used for maintenance.
48.3.14 Transceiver
The following user functions, related to the transceivers, are available in
the OMT:
Switch on QIU, switch on subjective speech quality improvements
uplink for one or more traffic channels within one transceiver
1)
Switch off QIU
1)
1)
Facilitates BER measurements according to /GSM:11.20/ and /
GSM:05.05/.
Monitor maintenance data, display any of the following data and
update changes continuously
Transmission and reception
Timing advance
390 (485)
EN/LZT 720 0008 P2A
2001-11-28
© Ericsson Radio Systems AB
All Rights Reserved
Preliminary