Reference Manual
BTS Parameter Limitations
58.3.13 IS Connection List
BTS-supported value range:
ICP: 4 – 127
(dec)
132 – 351
(dec)
512 – 583
(dec)
640 – 711
(dec)
CI: 1 – 72
(dec)
The IWD-defined value ranges:
ICP: 0 – 1023
(dec)
CI: 1 – 255
(dec)
Note: There are limitations for specific combinations. For more
information see the figure in Appendix.
58.3.14 Local Access State
BTS-supported value range:
Local Access State parameter: 0
IWD-defined value range: 0 – 1
58.3.15 MO Identifier
Table 186 BTS-supported/IWD-defined value range
MO class BTS-supported value (hex) IWD-defined value (hex)
Instance number Instance number
TRXC
01 00 – 0B 01 00 – 0F
TX 0B 00 – 0B 0B 00 – 0F
RX 0C 00 – 0B 0C 00 – 0F
58.3.16 MO State
Table 187 BTS-supported codes
Code MO State Parameter Used by MO
00 Reset CF, IS, TRXC, RX, TF, TS, TX, DP, CON
01 Started CF, TRXC
02 Enabled IS, RX, TF, TS, TX, DP, CON
03 Disabled IS, RX, TF, TS, TX, DP, CON
IWD-defined value range: 00 – 03
58.3.17 Power
Note: Only the following macro configurations are supported:
RBS 2101, RBS 2102 and RBS 2202 with configurations
1x2, 2x2, 3x2, CDU-A for 900 MHz, CDU-A with TMA for
1800 MHz and 1900 MHz.
EN/LZT 720 0008 P2A
2001-11-28
465 (485)
© Ericsson Radio Systems AB
— All Rights Reserved —
Preliminary