Reference Manual

Product Data RBS 2106
1300
65
125
650
725
1150
1235
710
50
355
665
P002771A
20 O mm
Front
Unit of measurement: mm
Figure 36 Drilling template for RBS 2106. Distance between holes is identical to that of
RBS 2102.
Weight
Table 46 RBS 2106 weights
Unit Weight
Fully equipped including batteries 590 kg
Fully equipped excluding batteries 550 kg
Door with climate unit 150 kg
Space Requirements
Installation and maintenance require that the door can be opened at least
90
. In practice this means that the space in front of the cabinet must be
kept clear for a distance of 1300 mm, see figure below. No free space is
needed at the back of the cabinet.
EN/LZT 720 0008 P2A
2001-11-28
95 (485)
© Ericsson Radio Systems AB
All Rights Reserved
Preliminary