Safety Instructions Part 4

SAFETY INSTRUCTIONS 13 (28)
BRU3 MANUAL, Doc.no: 124 46-ANNA 805 08 Uen Rev G, 2003-06-10
Figure 6 This label is used inside the BRU3 containing beryllium oxide. In
the future it should also be used on the lid of the bigger metallic
cover on the FE Radio Board for 900 MHz. The FE Radio Board
for 400 MHz does not have this extra cover. “Instruction book”
refers to this manual.
Figure 7 This label is used on the metallic lid covering the Beryllium Oxide
Ceramic Component.
5.2.8 Locating and Removing the Beryllium Oxide Component
Suitable tools:
A standard screwdriver
A TORX TX10 screwdriver
A pair of cutting pliers
A small adjustable spanner or an 8 mm spanner
CAUTION!
Before any part of the BRU3 is dismantled, all connections to power supply
must be disconnected.
1. Please read the whole section before taking any action.
2. Unlock and open the BRU3.
The Beryllium Oxide component is included on the FE Radio Board. The FE
Radio Board is underneath one of the filter modules, see Figure 8.
BERYLLIUM OXIDE
(Toxic)
used in the equipment.
See Instruction book.
!
P
oi
s
on
B
e
O