Masterclock Product Catalog 2012-2013
Master Clock Overview 1.0 Multi-functional and Dedicated Master Clocks What is a Multi-functional Master Clock? A Multi-functional Master Clock is capable of generating/receiving and outputting multiple time signals for system wide (and cross system) time synchronization.
Multi-functional Master Clocks 1.1 MCR1000 Reference Options • GPS • NTP • Time Code • High Stability Oscillator • NMEA 0183 • NENA 911 PSAP Standard Output Options • NTP • Time Code • Truetime/Kinemetrics • NMEA 0183 • NENA 911 PSAP Standard • PPO • PPS • 10MHz sine wave The MCR1000 Master Clock Reference system is a compact, precision time and frequency device.
Multi-functional Master Clocks 1.2 MCR5000 Reference Options • • • • • • GPS NTP Time Code High Stability Oscillator NMEA 0183 NENA 911 PSAP Standard Output Options • • • • • • • • NTP Time Code Truetime/Kinemetrics NMEA 0183 NENA 911 PSAP Standard PPO (Programmable Pulse Output) PPS (Pulse Per Second) 10MHz sine wave The MCR5000 Master Clock Reference system is a 1U rack mount, precision time and frequency device. Able to install more modules than the MCR1000.
Multi-functional Master Clocks 1.
Multi-functional Master Clocks 1.3.
Multi-functional Master Clocks 1.3. 2 MCR-TCR Module Key Features • • • • • Masterclock’s MCR-TCR (Time Code Reader) is an add-in module option for Master Clock Reference devices which reads and synchronizes to SMPTE or IRIG-B time code. Affordable price and flexible order options make this a popular add-in for synchronizing to time code in broadcast, industry, power distribution and monitoring as well as for specialized military applications.
Multi-functional Master Clocks 1.3.
Multi-functional Master Clocks 1.3. 4 NMEA Input/Output Info Key Features • Reads, synchronizes to, and outputs NMEA‐0183 ASCII Messages • NMEA code transmitted over Ethernet, RS‐232 and USB ports • Software controlled • Supports multiple baud rates from4,800 to 57,600 • May be added to MCR1000 and MCR5000 Masterclock’s MCR‐NMEA is an add‐in firmware option for Master Clock Reference devices which reads and synchronizes or outputs NMEA‐0183 messages.
Multi-functional Master Clocks 1.3.
Multi-functional Master Clocks 1.3. 6 MCR-PPO Module Key Features • User programmable pulse width • .0001 to 214,747 seconds (approximately 2.
Multi-functional Master Clocks 1.3. 7 Other MCR Add-ins Display Modules 6 Digit Display Module - MCR1000 9 Digit Display Module - MCR1000 6 Digit Display Module - MCR5000 2-6 Digit Display Modules - MCR5000 Event Time Software MCR Event Time allows one to easily make a schedule for activating a relay1 built into both of the MCR units. Up to 128 events can be scheduled per day. An MCR without this software is limited to one scheduled relay. 1 Masterclock, Inc.
Dedicated Master Clocks 2.1 NTP100-GPS FEATURES • NTP Reference for Ethernet LANs in self-contained box • Time synchronized to atomic clock in GPS satellites providing Stratum 1 accuracy • NTP query(unicast), multicast, or broadcast modes • Assignable network configuration • Telnet or serial interface – Discovery Tools included.
Dedicated Master Clocks 2.2 NTP100-GPS-HS FEATURES • NTP Reference for Ethernet LANs in self-contained box • Time synchronized to atomic clock in GPS satellites providing Stratum 1 accuracy • Typical holdover stability of 1ppb/day (<7 sec/year) using high precision internal OCXO during GPS loss. • NTP query(unicast), multicast, or broadcast modes • Assignable network configuration • Telnet or serial interface – Discovery Tools included.
Dedicated Master Clocks 2.
Dedicated Master Clocks 2.4 NTP100-OSC-HS FEATURES • NTP Reference for Ethernet LANs in selfcontained box • NTP time synchronized to an internal precision oven controlled crystal oscillator (OXCO) for typical stability of 1 ppb/day (< 7 sec/year) after 30 days of aging.
Dedicated Master Clocks 2.
GPS Referred Master Clock GPS500 FEATURES • • • • • • Generates SMPTE / EBU or IRIG‐B Time Codes Synchronized to atomic clocks in GPS satellites ‐11.
Dedicated Master Clocks 2.7 TCO100 FEATURES • Generates 30 fps SMPTE, 25 fps EBU, 24 fps FILM or IRIG-B (modulated and unmodulated) time codes • Functions as a backup time code source for master clock systems • Can be connected to GPS-200 master clock generator to automatically synchronize to GPS atomic clock time. Upon failure or removal of GPS-200 the TCO-100 will revert to a highly stable internal crystal oscillator and continue to provide an accurate time code output.
Rack Mount Network Time Clock NTDS16 FEATURES • 1” (2.
Rack Mount Network Time Clock NTDS19 FEATURES • • • • • • • • • 1” (2.
Rack Mount Network Time Clock NTDS112 FEATURES • • • • • • • • • 1” (2.
NTP Driven Clocks 3.2. 1 NTDS24 FEATURES • 2.3" (5.
NTP Driven Clocks 3.2. 2 NTDS26 MOUNTING BRACKETS FEATURES • 2.3" (5.
NTP Driven Clocks 3.2. 3 NTDS29 FEATURES • 1.8” (4.6cm), 9 digit LED – display colors available are red with green and amber on special order.
NTP Driven Clocks 3.3. 1 NTDS44 FEATURES • 4" (10.
NTP Driven Clocks 3.3. 2 NTDS46 FEATURES • 4" (10.
NTP Driven Clocks 3.4.
NTP Driven Clocks 3.4.
NTP Driven Clocks 3.5. 1 NTDS4626 FEATURES • Time and date display with 6 ‐ 4" (10.2cm) digits and 6 ‐ 2.3” (5.8cm) digits • Display colors available in red, green, amber, or blue • Syncs to external or internal NTP source for accurate traceable time • Display time in 12 or 24 hr format – hh:mm:ss • Display date in dd:MM:yy, MM:dd:yy, or yy:MM:dd • Adjustable brightness levels • All international time zones and automatic daylight saving times • Standard chassis is brushed stainless steel.
NTP Driven Clocks 3.5. 2 NTDS4626-3AL Black Powder Coat Chassis Stainless Steel Chassis FEATURES • Time and date display with 6 ‐ 4" (10.2cm) digits, 6 ‐ 2.3” (5.8cm) digits and 3 alphanumeric digits – display colors available in red, green, amber, or blue.
NTP Driven Clocks 3.5. 3 NTDS8646SS FEATURES • Time and date display with 6 ‐ 7" (18cm) digits and 6 ‐ 4” (10.
NTP Driven Clocks 3.6.
NTP Driven Clocks 3.6. 2 CLKNTD15 FEATURES • 14.9” (37.
NTP Driven Clocks 3.6.
NTP Driven Clocks 3.6.
NTP Driven Clocks 3.7 Dual Face Specs. Digital Clocks 4 Digit NTDS24DF Size: 10.3w x 7h x 3.5d in 25.9w x 17.8h x 8.4d cm Weight: 4 lbs 1.8 kg NTDS44DF Size: 15.75w x 9.5h x 3.5d in 40w x 24h x 9d cm Weight: 8.6 lbs 3.9 kg NTDS84DF Size: 26w x 10h x 4.5d in 66w x 25.4h x 11.4 cm Weight: 11.7 lbs 5.3 kg NTDS26DF Size: 15.5w x 7h x 3.5d in 39.5w x 18h x 9d cm Weight: 6 lbs 2.7 kg TCDS26DF Size: 15.5w x 7h x 3.5d in 39.5w x 18h x 9d cm Weight: 6 lbs 2.7 kg NTDS46DF Size: 25w x 9.5h x 3.
Timer Controller 3.
Time Code Driven Clocks 4.1 TCD200 FEATURES • 6 each, .6" – 1.5 cm digits, 7 segment LED – display colors available in red, green, and amber • Syncs to IRIG-B, SMPTE, EBU (also 24 fps film and drop frame) time codes • 24 or 12 hour time display – PM indicator • Time display - hh:mm:ss • Date display - MM:dd:yy - or - dd:MM:yy – internal switch configurable • -11.
Rack Mount Time Code Clock TCDS16 FEATURES • 1” (2.
Rack Mount Time Code Clock TCDS19 FEATURES • 1” (2.
Rack Mount Time Code Clock TCDS112 FEATURES • 1” (2.
Time Code Driven Clocks 4.3. 1 TCD24 MOUNTING BRACKET FEATURES • 2.3" (5.8cm), 4 digit LED – display colors available in red, green, Wall Mount amber, and blue Bracket • Syncs to IRIG-B and SMPTE, EBU non-drop frame time codes • Automatic time code type detection and input level control • Display time in 12 or 24 hr format – hh:mm • Display date MM-dd or dd-MM • Brightness control - 8 levels - switch configurable • -11.
Time Code Driven Clocks 4.3. 2 TCD26 FEATURES • 2.3" (5.8cm), 6 digit LED – display colors available in red, green, amber, and blue • Syncs to IRIG-B and SMPTE, EBU non-drop frame time codes • Automatic time code type detection and input level control Rack Mount Clock • Display time in 12 or 24 hr format – hh:mm:ss • Display date MM-dd-yy or dd-MM-yy - switch configurable • Brightness control - 4 levels - switch configurable • -11.
Time Code Driven Clocks 4.3. 3 TCDS26 FEATURES • 2.3” (5.
Time Code Driven Clocks 4.3. 4 TCDS29 FEATURES • 1.8” (4.6cm), 9 digit LED – display colors available are red with green and amber on special order.
Time Code Driven Clocks 4.4. 1 TCD44 MOUNTING BRACKET FEATURES • 4" (10.2cm), 4 digit LED – display colors available in red, green, Wall Mount amber, and blue Bracket • Syncs to IRIG-B and SMPTE, EBU non-drop frame time codes • Automatic time code type detection and input level control • Display time in 12 or 24 hr format – hh:mm • Display date MM-dd or dd-MM • Brightness control - 8 levels - switch configurable • -11.
Time Code Driven Clocks 4.4. 2 TCD46 FEATURES MOUNTING BRACKET • 4" (10.2cm), 6 digit LED – display colors available in red, green, Wall Mount amber, and blue Bracket Option • Syncs to IRIG-B and SMPTE, EBU non-drop frame time codes • Automatic time code type detection and input level control • Display time in 12 or 24 hr format – hh:mm:ss • Display date MM-dd-yy or dd-MM-yy - switch configurable • Brightness control - 4 levels - switch configurable • -11.
Time Code Driven Clocks 4.5 TCD86 FEATURES MOUNTING BRACKET • 8" (20.3cm), 6 digit LED – display colors available in red, green, Wall Mount amber, and blue Bracket Option • Syncs to IRIG-B and SMPTE, EBU non-drop frame time codes • Automatic time code type detection and input level control • Display time in 12 or 24 hr format – hh:mm:ss • Display date MM-dd-yy or dd-MM-yy - switch configurable • Brightness control - 4 levels - switch configurable • -11.
Time Code Driven Clocks 4.6. 1 CLKTCD12 Standard Faceplate 12/24 Hour Option True 24 Hour Option Dual Face Option (see 3.7) FEATURES • SMPTE, EBU and IRIG-B (modulated and unmodulated) time code driven • Self-correcting to non drop frame time code • -11.
Time Code Driven Clocks 4.6. 2 CLKTCD15 FEATURES • 14.9” (37.85cm) analog clock • SMPTE, EBU and IRIG-B (modulated and unmodulated) time code driven • Self-correcting to non drop frame time code • -11.
Time Code Driven Clocks 4.6. 3 CLKTCD18 FEATURES • 18” (45cm) analog clock • SMPTE, EBU and IRIG-B (modulated and unmodulated) time code driven • Self-correcting to non drop frame time code • -11.
PCIe with Time Code Reference Input PCIe-TCR PCIe‐TCR card references Time Code sources. Accepts time code formats: SMPTE (Non‐Drop Frame), EBU, NDF and IRIG‐B0 and ‐B1 Increase long‐term accuracy and holdover with an HSO (high stability oscillator) option.
PCIe with GPS Reference Model # PCIe-GPS The Masterclock PCIe‐GPS card receives reference time from atomic clocks orbiting in GPS (Global Positioning System) satellites to provide the most accurate time and date information for a Windows PC. See the User Manual for additional GPS information available through API. Increase long‐term accuracy and holdover with a HSO (high stability oscillator) option.
PCIe with Internal Oscillator PCIe-OSC PCIe‐OSC card provides very stable, accurate time and date information for a Windows PC. Configuration options include GPS or Time Code inputs. Increase long‐term accuracy and holdover with an HSO (high stability oscillator) option.
PC Cards 5.
PC Cards 5.2 GPSPCI FEATURES • • • • • • • • Synchronizes PC to atomic clock in GPS satellites with ± 1μ sec accuracy Software is supplied for operation under Windows 98/ME/NT2000 and XP APIs provided for custom programming High stability oscillator and clock with battery backup On board LED indicates GPS lock GPS information and PPS timing pulse available via DB9 Optional software ‐ TCRSync‐NTP provides NTP reference for heterogeneous operating systems on an Ethernet LAN, based on GPSPCI.
PC Cards 5.
PC Cards 5.
Time Code Interfaces 6.1 TCC100 FEATURES • CONVERTS time codes TO PARALLEL BCD • Reads - smpte - (Including - EBU, film & drop frame) – IRIG-B • Outputs parallel BCD time information • Output format is directly compatible with Utah Scientific mc-500 series switchers • 120/240 VAC with supplied external wall mounted power supply or 12 VDC operation.
Time Code Interfaces 6.2 TCC500 FEATURES • Reads - SMPTE (including EBU, film & drop frame) and IRIG-B • Outputs parallel BCD time with 8 digit or one millisecond resolution - hh:mm:ss:ms-(frames) • 120/240 VAC with supplied external wall mounted power supply or 12-28 VDC operation.
Time Code Interfaces 6.
Time Code Interfaces 6.
Time Code Interfaces 6.
Time Code, RF & Pulse Amplifier DA12 DA12 SPECS • • • • 2 inputs: 1/12 or 2/6 input/output Output banks are selectable AC or DC coupled Dual isolated output banks Standard chassis color is black powder coat INPUTS ‐ 2 • RF Frequency Level Impedance Isolation A to B 0 Hz – 20 MHz 1 V rms [15 dBm max] 50 Ω or 600 Ω >85 dB • Pulse /DC IRIG Time Code Frequency Level Duty Cycle Impedance • AM IRIG Time Code Frequency Level Modulation Frequency Code Format Impedance 1PPS to 10 MPPS 0‐7V p‐p 0 to 100% 50 Ω o
Time Code Interface Model # The TCS100 is an automatic time code changeover unit designed to provide automatic or manual switching between two time code sources. FEATURES TCS 100 Rack mountable with RM4 • Accepts SMPTE / EBU or IRIG‐B (modulated and unmodulated TC) • Automatically determines TC type and switches to the alternate source if TC is lost or if a problem is detected in the primary TC source.
Bell Ringing System CRL 1000 FEATURES • • • • • • • • • • Four circuit programmable bell controller synchronized to network time (NTP) Industrial or institutional bell ringer system Reference external NTP source or use internal clock with accuracy of ±1 minute per year Executes up to 256 schedule events per day Circuits may be scheduled independently Schedule in 12‐ or 24‐hour format Front panel displays time or date of internal clock and LED indication of relay activation Provides 24VAC, 16 Amps (400VA)
Bell Ringing System 7.
Power Supplies 9.1 PSU45 Combines power needs for an orderly installation of Masterclock equipment. Mounts in RM4 rack mount to supply 28V power for up to 9 Masterclock rack mounted devices.
Power Supplies 9.2 PSPOE15 Allows power to be transferred over unused pairs of CAT5/6 Ethernet cable. Saves on installation cost of wiring power to PoE compliant Ethernet devices. FEATURES • Compliant with IEEE802.
Power Supplies 9.3 Cisco SF302-08MP – 8 port PoE switch • • • • Standards-based IEEE 802.3af Power over Ethernet (PoE) Up to 8 ports at 15.4W Dual Gigabit uplinks provide increased bandwidth and redundancy 802.
GPS Instruments 10.1 Antennas and Mounts Standard GPS Antenna The standard antenna, coaxial cable and antenna mounting hardware come standard with GPS-referenced Masterclock equipment packages. The GPS-based product includes the antenna, coaxial cable with connectors, and antenna mounting. This antenna can be mounted either indoor or outdoor so long as it is exposed to the sky. The antenna was initially designed for external mounting in marine environments.
NTP GPS Driven Instruments Clocks 10.2 SA90 SA90-SMA Surge Arrestor (supplied with surge arrestor and SMA female to SMA male cable) Broadband Surge Arrestor for DC-3000 MHz applications Help protect your equipment from the effects of lightning induced surges with the broadband SA90-SMA Surge Arrestor. This DC-passing surge arrestor operates with frequencies up to 3 GHz and helps with protection from lightning strikes. The arrestor is compatible with the IEEE 802.11b standard.
GPS Instruments 10.2 SA90 SURGE ARRESTOR INSTALLATION WARNING Ensure that the antenna and coaxial cable that the surge arrestor is protecting is not exposed to direct lightning strikes. This device offers no protection for such strikes and will be destroyed – along with whatever equipment that it is connected to - by a direct strike. Notice: The installation, maintenance, or removal of antenna and surge arrestor systems requires qualified, experienced personnel.
Rack Mount Bracket RM4 Anodized Aluminum Rack Mount Kit provides a sleek, compact, rack ready housing for up to four of our devices. RM4 FEATURES • • • Houses up to 4 Masterclock units Blank panels are supplied for any unused spaces Components can be easily installed or removed in the field SUPPORTED DEVICES • GPS200 • MCR1000 • NTP100 • TCA100 • TCC100 • TCC500 • TCD200 • TCI232 • TCI500 • TCINENA • TCO100 • TCS100 SIZE • • Standard 1RU. 19” x 1 ¾” (48.25 cm x 4.
Information i Company History Masterclock's predecessor company - Clark and Associates - was founded by William (Bill) Clark in 1986 to build automation systems for the Radio & TV industries. Masterclock itself was incorporated as an entity in 1994. Starting with a two person operation in the proverbial home garage it has grown into a successful enterprise doing multi-million dollars in business throughout the world.
Information ii NTP & Time Code NTP Network Time Protocol (NTP) is an open standard Internet protocol that utilizes standard Ethernet wiring to synchronize computers, clocks, networks and other systems to an NTP reference server. The signal can be transmitted over LAN and WAN wired networks and over various wireless systems. There are numerous public sources of NTP available.
Information iii Benefits of PoE Power-over-Ethernet (PoE) extends the versatility for system designers and companies. No longer will one have to locate access points within the typical six foot electrical cord reach of an AC outlet or look for convenient locations to install new outlets at points where its suitable to run conduit and mount outlet boxes. PoE only requires technicians to run one Ethernet cable – CAT5 or CAT6- to the access point for supplying both power and data.
Information iv Domestic Ordering General • We accept VISA and MasterCard credit cards. • We accept Purchase Orders from firms and institutions with acceptable credit. • All items are generally in stock for immediate shipment. • Orders can be shipped COD. • We offer a 30 day satisfaction guarantee on all of our products.
Information v International Ordering TERMS OF SALES • Prices are net US dollars, FOB, our plant.
Information vi Major Customers Other customers include: Aberdeen, Abu Dhabi International Airport, Australian Broadcasting, BBC, CBS, Chicago Cubs, Court TV, Ericsson, General Electric, Hughes, Hydro Quebec, IBM, Intel, Leitch Video, Lockheed Martin, NASA, Naval Space Technology Labs, NPR, Numerous PSA/Call Centers throughout the globe, Raleigh Durham Airport, Royal Canadian Mounted Police, Sky Channel, Sony Systems, TeleMetropole, Time Warner Cable, UCLA, University of Missouri, US Air Force, US Army, US
Information vii Suggested Functional Specs. SUGGESTED FUNCTIONAL SPECIFICATION for a GPS Synchronized Clock System using Network Time Protocol and Power over Ethernet 1.1 SCOPE This document specifies a wired clock system that relies on the accuracy of the Global Positioning Satellite (GPS) system for synchronizing the time provided to clocks and network devices using the Network Time Protocol (NTP).
Suggested Functional Specs. Continued - 2 2.0 REQUIREMENTS 2.1 GENERAL SYSTEM REQUIRMENTS The synchronized clock system shall meet or exceed the requirements of this specification in all aspects. 2.
Suggested Functional Specs. Continued - 3 Accuracy: The networks clock displays shall be accurate to within 50 milliseconds of the UTC time reference provided by the NTP server(s), when synchronized. Protocol: The Ethernet wired clocks shall support the following protocols: SNTP, Simple Network Time Protocol The network clocks shall operate with an internal reference time that is set to UTC (Universal Coordinated Time) via a built-in the SNTP client, from up to two NTP timeservers.
Suggested Functional Specs. Continued - 4 During such “free-wheeling” periods and while in operation, the network clocks shall provide a visual indication that the device is relying on the internal oscillator and is not currently synchronized to the network timeserver. 2.3.2 Analog clock engineering specification: The shape of the analog clock shall be round 12” [30 cm] or 18” [46 cm]. The face of the clock shall be off-white, the time indication marks on face shall be black.
Suggested Functional Specs. Continued - 5 4.0 REPAIR AND MAINTENANCE Designed as solid-state devices, the clocks shall require no standard maintenance and shall have no user serviceable or replaceable parts inside in order to reduce the requirement for on-site maintenance and repair personnel. Any necessary firmware updates shall be made available and able to be applied on location. Instructions and required update files shall be made available for download from the manufacturer’s website.
Information viii System Operations Time synchronization is more crucial than ever before. It has also never been easier to accomplish. Masterclock provides complete solutions using open standards like NTP (Network Time Protocol) and SMPTE/IRIG time code. Just one device can receive atomic clock time and output it to both NTP Masterclock, Inc. January and time code.
Information ix Warranty Information LIMITED HARDWARE WARRANTY This Masterclock, Inc. (hereinafter Masterclock) product warranty extends to the original purchaser. Masterclock warrants all electronic hardware products against defects in materials and workmanship for a period of one year from date of sale. If Masterclock receives notice of such defects during the warranty period, Masterclock will, at its option, either repair or replace products, which prove to be defective.
Information x Warranty Information LIMITED SOFTWARE WARRANTY To the original customer only, Masterclock, Inc.(hereinafter Masterclock) provides the following Limited Warranty. 30 Day Satisfaction Guarantee For thirty (30) days after date of delivery of the SOFTWARE to you, if you are dissatisfied with the SOFTWARE for any reason you may return the complete product, with your receipt, to Masterclock, postage prepaid, during the thirty (30) day period for a full refund.
SOME STATES DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES, SO THE ABOVE EXCLUSION MAY NOT APPLY TO YOU. IN THAT EVENT, ANY IMPLIED WARRANTIES ARE LIMITED IN DURATION TO NINETY (90) DAYS FROM THE DATE OF DELIVERY OF THE SOFTWARE. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY HAVE OTHER RIGHTS, WHICH VARY FROM STATE TO STATE.
RMA xi Return Information and Procedure RMA Instructions Step 1: Read this RMA policy statement Step 2: Complete the RMA form and sign Step 3: Fax RMA form to (636) 724‐3776 or email support@masterclock.com Step 4: Receive faxed or emailed RMA number from Technical Support Step 5: Print the RMA number on the outside of the shipping box Step 6: Ship product(s) to: Attn: RMA#_____ Masterclock, Inc. 2484 West Clay Street Saint Charles, MO 63301 RMA numbers are valid for 30 days.
Exchange: Refers to returning items to receive different product Items that are returned for credit or exchange due to a mistake on customer's part (ordered wrong, end user changed their mind, improper installation, etc.) will be exchanged only after receipt of authorization for payment for 15% of item value with a minimum charge of $50. After 30 days – all sales are final.
Filling out RMA Request Form 1. RMA numbers will be issued only with the proper Masterclock’s invoice number. 2. You must provide a reason for the product return. If defective, please provide a detailed description of the problem. 3. Mark the action you desire to be taken in regards to your RMA ‐ Credit, Exchange, Upgrade, Warranty Repair or Non‐warranty Repair. If you are requesting an exchange, please indicate which items/quantity you wish to exchange for. Shipping Items 1.
Masterclock’s RMA Request Form RMA# PLEASE SEE ATTACHED RMA TERMS & CONDITIONS FOR ADDITIONAL DETAILS Date: __________________________________ Company Name: _________________________________ Address 1: ______________________________ Address 2: ______________________________________ City: ___________________________________ State/Country: ________ Contact Person: __________________________ Phone: _______________ Fax: ____________________ Quantity Model # Serial # Zip/Code: _______________ Invoi
CUSTOMER REQUEST FOR CREDIT This is a request for net 30 days credit from date of shipment. We understand and agree that if payment is not received by Masterclock within 30 days of shipment date then a 1.5% charge will be added for each month or part thereof that the payment is late. Please print or type and complete all sections fully.
Masterclock, Inc. 2484 West Clay St. St. Charles, MO 63301 +1-(636)-724-3666 1-800-724-1778 support@masterclock.com sales@masterclock.