Specifications

Masterclock, Inc.
phone(USAandCanada):18009402248|phone(international):+16367243666
email:sales@masterclock.com|online:www.masterclock.com
FEATURES
Fourcircuitprogrammablebellcontrollersynchronizedtonetworktime(NTP)
Industrialorinstitutionalbellringersystem
ReferenceexternalNTPsourceoruseinternalclockwithaccuracyof±1minuteperyear
Executesupto256scheduleeventsperday
Circuitsmaybescheduledindependently
Schedulein12‐or24hourformat
FrontpaneldisplaystimeordateofinternalclockandLEDindicationofrelayactivation
Provides24VAC,16Amps(400VA)withcurrentlimitedoutputsat4ampseachcircuit
Drivesupto20,24VACbellspercircuit(80totalbellsat200mAeach)
Masterinputterminalallowsallbellstoberungwithexternalswitchclosure‐
usableformasteralarmssuchasfireorgeneralevacuation
OptionalBells
6in(150mm)24VAC,.170A,91dB@10'(3m)typical
10in(250mm)24VAC,.170A,94dB@10'(3m)typical
Bell Ringing System
CRL 1000
SPECIFICATIONS
ConfigurationandSchedulingSoftware
SupportsDHCP/BOOTPforautomaticacquisitionof
networkaddress,nameservers,andtimeserver
configuration
NTPsynchronizationoptions,andmore
Providesdynamicconfigurationfornetworking
parameters,timezone/daylightsavingstime
ConfigureclocksthroughprovidedWindowsnetwork
discoverysoftwareorTELNET
Configurationissavedtononvolatilememoryand
survivespowerlosses
Encryptednetworkmessagespreventunauthorized
tamperingofconfiguration
Physical
Size:
19wx3.5hx9.25din
Weight:
19.5lbs
48.3wx8.9hx23.5dcm 8.6kg
Connectors:
Ethernet‐RJ45
ACinput‐IECconnector
TerminalBlock,24VACwiringtobells
4eachindividualswitchcircuitbreakers‐
1foreachbellcircuit
Chassis
Rackmountedweldedsteelchassiswithremovablerackears
Blackoroffwhitepowdercoatpaint
Power
Powerinput120/240VAC,50/60Hz
IncludesACinputpowercord
OperatingTemperature
Temperature:0to+70°C