User`s guide
2(2)
Datum/Date Rev
Dokumentnr/DocumentnrUppgjord/Prepared
Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Tillhör/Referens-File/Reference
98-01-26 A
116/155 34-ASB 150 02 Uen
FACILITY DESCRIPTION
Faktaansvarig - Subject responsible
Limitations
• Each extension can only set up one monitoring
task to a trunk or route. However an extension
can set up several internal monitoring tasks that
run concurrently with the external one.
• If the ordering extension activates "follow me" or
"diversion" during the monitoring will not be
affect.
• Callback is activated when both ordering exten-
sion and trunk are free at the same time.
• If the monitored parties are not free at the same
time during a 30-minutes period, monitoring will
be terminated
Programming
Following commands are only accessable via
RASC:
2008
Verification on call back
The system supplies normal verification tone when it
accepts an order. This can be altered so that silence is
received instead.
valid data: YES (verification tone)
NO (silence)
default data: YES
2402
Call back
Altering the digit for ordering. The postdialling digit for
callback is normally "5" but this digit can be changed.
1006
Call back allowed ?
Each trunk can be programmed so that callback to the
trunk is prevented.
3302
Callback allowed ?
Each route can be programmed so that callback to the
route is prevented.
Equipment
None.