User`s guide

4(8)
Datum/Date Rev
Dokumentnr/DocumentnrUppgjord/Prepared
Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Tillhör/Referens-File/Reference
98-05-29 D
140/155 34-ASB 150 02 Uen
FACILITY DESCRIPTION
Faktaansvarig - Subject responsible
6332
Log minimum costs
This command can be utilised if it is desired to log
outgoing calls, but exclude those calls that have
incurrent "few" costs.
The command is used to determinate the minimum
costs required for an outgoing call to be logged.
valid value 0 - 999999999 costs
default value 0
With the minimum cost = 0,0 outgoing external calls
will be logged irrespective of the cost.
6304
Bar outgoing calls ?
In certain cases, e.g. when external/peripheral
equipment for storage of call data is out of order, the
desired logging is not possible. Using this command it
is possible to select whether to permit subsequent
outgoing external calls without logging or to restrict
such calls until logging is again possible.
Note that it is always possible for the operator to
initiate outgoing external calls irrespective of the value
of this command.
6305
Dialled number suppress
Suppression of the last digits in the dialled number.
The desired number of end digits can be stated with an
"X" on the printout, if you for security reasons do not
want to show the complete external number.
Valid data: 00 - 15
Default data: 00 (all digits are registered)
6306-6315
Registration of calls which start with a certain digit
Every trunk line can be programmed in such a way,
that the first digit in the trunk line decides if an output is
to be carried out.
6203
Block log output
The command is used when a temporary stop of
logged call data is desired. During temporary stops in
output the logged call data will be stored internally in
the PABX. Temporary stops in output can be desirable
during maintenance of connected external/peripheral
equipment, e.g. in order to insert paper in a printer.
It should be noted that only a limited number of call
records can be stored internally in the PABX. If the
PABX's internal storage capacity is exceeded, it may
be decidee whether or not to block outgoing external
calls from the PABX, see command 6304.
COMMUNICATION CHANNELS
6006
Device type
The command defines to which type of connected unit
the I/O-port is to be adapted.In some cases, master/
slave must also be stated by means of command
6010. When programming the unit, the values of
several parameters adapted for the connected unit will
be set automatically.
Please note that using the V.24 bi-directional you have
to state value 13 !
Unit values :
- 0 = Unspecified
- 1 = Operation and maintenance centre (O&M)
with ECOM/ECEL
- 2 = Unspecified printer/terminal
- 3 = Printer type 1
- 4 = Printer type 2
- 5 = Computer for administration of call information
logging (CIL),
- 6 = Computer for administration of call information
logging (CIL),
- 7 = Unspecified printer/terminal
- 8 = Connection to computer with standard hotel line
protocol. The PABX is master, the hotel
computer is slave.