User`s guide

5(8)
Datum/Date Rev
Dokumentnr/DocumentnrUppgjord/Prepared
Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Tillhör/Referens-File/Reference
98-05-29 D
140/155 34-ASB 150 02 Uen
FACILITY DESCRIPTION
Faktaansvarig - Subject responsible
- 9 = Connection to computer with standard hotel line
protocol. The PABX is master, the hotel
computer is slave.
- 10 =Connection to computer with line protocol
type 3.
- 11 =Operation and maintenance centre (O&M
centre) with RASC and MIS
- 12 =Connection to computer with line protocol
type 2. The PABX is master, the hotel computer
is slave.
- 13 =Hotel computer, bi-directional V.24 interface with
line protocol type 4.
6007
Character set
The command defines which set of characters shall
apply for the local-connected unit for the stated I/O-
port .
0 = The PABX's internal set of characters (no
characters are converted)
1 = US-ASCII
2 = Swedish/Finnish ASCII
3 = Character set 2 in printer ERICSSON 7111
(strapped for compatibility with IBM-PC) and
character set 850 (Multilingual) for SOFTECH
hotel computer.
4 = Danish/Norwegian ASCII
5-9 = Undefined values
6009
Baud rate
The command determines the bit speed for the stated
V.24 port . The type of local-connected unit and set of
characters for the local-connected unit, commands
6006, 6007 and 6010 must be defined.
0 = The stated I/O-port will not permit local V.24
connections.
1 = 50 Baud 6 = 300 Baud 11 = 3 600 Baud
2 = 75 Baud 7 = 600 Baud 12 = 4 800 Baud
3 = 110 Baud 8 = 1 200 Baud 13 = 7 200 Baud
4 = 135 Baud 9 = 1 800 Baud 14 = 9 600 Baud
5 = 150 Baud 10 = 2 400 Baud 15 = 14 400 Baud
6010
PABX is master or slave in local connections
Determines whether the PABX is 'master' or 'slave'
when connected to certain types of local-connected
units.
The command determines whether the PABX will be
master or slave when connected to an external
equipment (V24).
This command will be ignored when connecting
certain types of external equipment (see command
6006).
6011
Autoselect allowed
Determines whether the port may be used by functions
which have no commands of their own for the
specification of a communications port.
Set this command to NO.
6012
Route on request
Controls connection requests initiated by external
equipment. This command should be empty (Spaces).