User`s guide

9(16)
Datum/Date Rev
Dokumentnr/DocumentnrUppgjord/Prepared
Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Tillhör/Referens-File/Reference
99-07-15 D
152/155 34-ASB 150 02 Uen
FACILITY DESCRIPTION
Faktaansvarig - Subject responsible
y 0: PBX is master
1: PBX is slave
For the current case (CTI usage) the command must
be set to “1” meaning that PABX is used as slave.
6011
Autoselect allowed?
This command allows to specify whether or not
automatic selection will be allowed when making local
connections of external equipment.
If the answer is no, the port will only be used by
services which have commands of their own for
selecting ports.
If the answer is yes, the port may also be selected by
services which have no command for the specification
of port.
aabb Line position
aa = board position
bb = individual number on board, shall be
00-02 (depending on the CPU-D_ or
AUX_ board used).
c Decides whether or not automatic
selection of this port is allowed.
Yes = allowed
No = not allowed (default value)
In the CTI case the command must be set to NO.
6012
Route on request
This command routes a connection request from the
externally connected equipment to the desired service
in the PBX.
aabb Line position
aa = board position
bb = Individual number on board, shall be
00-02 (depending on the CPU-D_ or
AUX_ board used).
c Enter the desired application used as
answering position for connection
requests. The default value is blank.
0 = not used for external connections
1 = Operation and Maintenance with
RASC
2 = ACD (MS)
3 = CTI
Equipment
ASB 150 02 system software R8 or higher and one
free V.24 port on the CPU-D_ or AUX_ board are
required.
Security Unit
Starting with R10, a security unit (also known as
FECU) is required for every site (with R10 software)
running BusinessLink for Novell. For detailed
information about FECU, please refer to document
FACILITY DESCRIPTION (155 34-ASB 150 02 Uen),
especially chapter 6, FUNCTIONALITY OF ASB 150
02 WITH/WITHOUT FECU.
10 Jul 14:40 +15˚
AUTOSELECT LOCAL 6011 aabb c
backward forward c/i return
10 Jul 14:40 +15˚
REROUTE ON REQUEST 6012 aabb c
backward forward c/i return