FAULT INDICATION
Definition
Fault indication enables the signalling of a fault as
selected in the RASC tables, on a digital system
telephone set with display.
Use
This function can be used when certain alarms
detected by the system should be signalled on a digital
system telephone set.
Operation
STANDARD-, EXECUTIVE Telephone and
OPERATOR Console.
There are a number of alarms that are detected by the
system which can be indicated on a digital telephone
set (e.g. LED lights on function key).
When the programmed function key indicates an
alarm, press the key and the following is displayed on
an:
EXECTUTIVE telephone
STANDARD telephone
Press "Enter" to clear this display and step to the next
masked alarms.
Capacity
This feature can be activated on all digital system
telephone sets with programmable function keys.
Limitations
Not available on analog telephones and on digital
telephone sets without programmable function keys.
Programming
ACCESSIBLE VIA RASC
To flag the warnings that are to be indicated, enter
under
Maintenance
/
logging
and select from
defined
codes
for example:
0302
Insert the code *91# on selected key to display all
flagged alarms.
Equipment
none
12 Feb 15:55 +22˚
ALARM (01) 1206 - 1415
CODE:C4-0510 FA-0105
ALARM(01)1206-1415
CODE:C4-0510 FA-0105
C1
C7
C4
SWITCH CHANNEL RELEASE ERROR
CALL METERING COUNTER OVERFLOW
--------
DIGITAL LINK REPORT
-W------
-A------
enter an "A" to activate fault indication