User`s guide
4(4)
Datum/Date Rev
Dokumentnr/DocumentnrUppgjord/Prepared
Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Tillhör/Referens-File/Reference
98-01-27 A
261/155 34-ASB 150 02 Uen
FACILITY DESCRIPTION
Faktaansvarig - Subject responsible
Programming
2080
Free on 2nd access Y/N ?
This command states if the system telephones have
"Busy on Line 2" or "Free on 2nd access" on Line 2.
default value YES ( access on Line 2 )
0301
Blocking Line 2 / Free on 2nd access
Extension users with system telephones who wish to
have "Busy on Line 2" / "Free on Line 2" need to use a
programmable key for this purpose.
xxxx Enter extension' s directory number
yy Enter relevant key (00 - 48)
zz Enter code for un/blocking key = 26
It is also possible to assign a key by means of
individual programming.
See chapter INDIVIDUAL PROGRAMMING in
document FACILITY DESCRIPTION,
155 34-ASB 150 02 Uen.
3038
Programm busy line ?
This command states which ACOS goup is permitted
to programm the facility "Busy Line 2".
default value YES
0101
Facility COS
This command states which facility the extension
belongs to. The facility category controls the number of
fac8ilities the extension has access to.
Extensions (and trunk lines) can be devided into 16
different facility categories.
valid falue 0 - 15
default value 0
Equipment
None.
10 Jul 14:40 +15˚
FUNCTION OF KEY 0301 xxxx yy zz
backward forward c/i return