User`s guide
17(31)
Datum/Date
Rev
Dokumentnr/Documentnr
Uppgjord/Prepared
Dokansv/Godkänd - Doc respons/Approved Kontr/Checked
Tillhör/Referens-File/Reference
99-07-15 C
265/155 34-ASB 150 02 Uen
FACILITY DESCRIPTION
Faktaansvarig - Subject responsible
Base Number
The peripheral number on the IC-LU / IC-CU2.
Valid numbers: IC-LU: 1 - 8 / IC-CU2: 1 - 4
NOTE: Max. 7 IC-LUs can be installed !
Delay
This delay value is needed to assure proper operation of handovers between Base Stations.
Use value 1 = Automatic delay
Change Base Station
Menu path: Distributor - Base Station - Change
This command changes the delay value of a Base Station. This delay is set by the `Add Base Station'
command. During the change action no calls can be made via the Base Station. It may be necessary to
change a delay value if:
- the Base Station has been connected to another cable of a different length or type,
- an incorrect delay value was entered,
- a defect Base Station must be replaced with a correctly functioning one.
Enter the board address (Cabinet and board number) and the Base number (Peripheral number).
Delete Base Station
Menu path: Distributor - Base Station - Delete
This command deletes a Base Station from the IC-CU_ data base. It is used if a Base Station is to be
removed from the IC system. During the delete action the Base Station may not have any existing calls.
Enter the board address (Cabinet and board number) and the Base number (Peripheral number).
Calls using the Base Station that is to be deleted are not terminated. Therefore, if the last call using the
Base Station is not terminated within 5 minutes of the request, the request is cancelled. If you still want
to delete the Base Station you have to select the delete command once again.
List Base Stations
Menu path: Distributor - Base Station - List
This command gives a list of Base Stations with their related data as defined in the IC-CU_ data base.
The settings shown have been defined by the Add Base Station command. The columns on the screen
have the following meaning:
Column 1 Cabinet Number
Column 2 Board Number of controlling IC-LU or IC-CU2
Column 3 Peripheral Number on IC-LU or IC-CU2
Column 4 Base Station Number (Base Station Identity)
Column 5 Delay value