User`s guide
21(31)
Datum/Date
Rev
Dokumentnr/Documentnr
Uppgjord/Prepared
Dokansv/Godkänd - Doc respons/Approved Kontr/Checked
Tillhör/Referens-File/Reference
99-07-15 C
265/155 34-ASB 150 02 Uen
FACILITY DESCRIPTION
Faktaansvarig - Subject responsible
Reset Tables
The Test and Maintenance software in the IC-CU_ maintains a number of reset tables that can be read
by the Cordless System Manager. These reset tables are meant for IC support specialists. In the case of
certain problems, you may be asked to send table loggings to your IC supplier.
Power on Reset
Menu path: Distributor - Diagnostics/test - Info - Reset table - Power on
This command displays the history of IC-CU_ Power-on resets (number of resets and time of last reset).
Watchdog Reset
Menu path: Distributor - Diagnostics/test - Info - Reset table - Watchdog
This command displays the history of IC-CU_ watch-dog resets (number of resets and time).
HSCX, HDLC A, HDLC B and 8032 Reset
Menu path: Distributor - Diagnostics/test - Info - Reset table - HSCX/HDLC A/HDLC B/8031
These commands display the number of resets of the following units on the CPU board: HSCX, HDLC
A, HDLC B and Board Controller (8032).
Absolute Reset
Menu path: Distributor - Diagnostics/test - Info - Reset table - Absolute
This command displays the number of resets and time of any last reset on the selected System Board.
Enter the position of the board (Cabinet and Board Number).
Relative Reset
Menu path: Distributor - Diagnostics/test - Info - Reset table - Relative
This command displays the number of resets and time of any last reset of the selected Peripheral (circuit
number 1 ... 8) and Board Controller (circuit number 9) on the System Board (does not include the IC-
CU_ board). Enter the position of the Peripheral (Cabinet, Board Number and Circuit Number).