User`s guide

25(31)
Datum/Date
Rev
Dokumentnr/Documentnr
Uppgjord/Prepared
Dokansv/Godkänd - Doc respons/Approved Kontr/Checked
Tillhör/Referens-File/Reference
99-07-15 C
265/155 34-ASB 150 02 Uen
FACILITY DESCRIPTION
Faktaansvarig - Subject responsible
Service Table
Menu path: Distributor - Diagnostics/test - Info - Error tables - Service
Menu path: System Manager - Control - Service
This command displays the contents of the Service Table. The Service Table contains error messages
meant for the field service technician.
System
Menu path: Distributor - Diagnostics/test - Info - System
Menu path: System Manager - Control - System
This command lists the states of the functional blocks in the IC-CU_. A functional block may be a
System Board or a circuit on a board.
Base Station List
Menu path: System Manager - Control - Base Station List
This command gives a list of Base Stations with their related data as defined in the IC-CU_ data base.
Replace Board
Menu path: System Manager - Control - Replace board
This command puts a System Board out of operation. It must be used if a System Board is to be
replaced by a board that must be of the same type and placed on the same position (e.g.: board is
defect).
When the Replace Board command is selected you must enter the board position (cabinet and board
number). During the replace action all peripherals on the board in question are blocked for new calls.
Calls using peripherals on a board that is to be replaced are not stopped. Therefore, if the
last call on the board is not terminated within 5 minutes of the request, the request is cancelled. If you
still want to replace the board you have to select the Replace Board command once again.
NOTE: Not applicable for the IC-CU_.
Remove Board
Menu path: System Manager - Control - Remove board
This command deletes a System Board from the IC-CU_ data base. It must be used to eliminate a
System Board (e.g.: board is replaced by another type, board is placed on another position in the
Cabinet). Other data that is related to the board must be deleted from the IC-CU_ database.
When the Remove Board command is selected you must enter the board position (cabinet
and board number). During the remove action all peripherals on the board in question are blocked for
new calls.
Calls using peripherals on a board that is to be removed are not stopped. Therefore, if the last call on
the board is not terminated within 5 minutes of the request, the request is cancelled. If you still want to
remove the board you have to select the Remove Board command once again.
NOTE: Not applicable for the IC-CU_.