User`s guide
31(31)
Datum/Date
Rev
Dokumentnr/Documentnr
Uppgjord/Prepared
Dokansv/Godkänd - Doc respons/Approved Kontr/Checked
Tillhör/Referens-File/Reference
99-07-15 C
265/155 34-ASB 150 02 Uen
FACILITY DESCRIPTION
Faktaansvarig - Subject responsible
Equipment
The following boards are necessary for the installation of the "integrated cordless":
• IC-CU
Integrated Cordless - Control Unit
based on the FREESET CPU ( DCT1800, A-protocol ).
or
IC-CU2
Integrated Cordless - Control Unit, Version 2
based on the IC-CU and IC-LU board, GAP protocol, each IC-CU2 offering:- 8 speech channels
- 4 ports for base stations
• IC-LU
Integrated Cordless - Line Unit
based on the FREESET SLU-board, each IC-LU offering: - 8 speech channels
- 8 ports for base stations
• FECU for IC-CU_
Feature Enabling Control Unit ( =plug in board for the IC-CU_ with SW-key for enabling configurations
of more than 8 portables. See also chapter CAPACITY in this document. )
• FECU for CPU-D4
Feature Enabling Control Unit ( =plug in board for the CPU-D4 with SW-key) that is mandatory using the
GAP-protocol (See also chapter CAPACITY in this document).
• PUB 5 or higher version
Backplane for ASB15002 system cabinet (only valid for BP 250).
The IC-CU_ and all IC-LU boards have to be mounted in the same cabinet (containing the backplane PUB 5 or
higher), but not necessarily in the first cabinet ( for more informations see document 1531-BDV 113 08 Uen ).