User`s guide

2(3)
Datum/Date Rev
Dokumentnr/DocumentnrUppgjord/Prepared
Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Tillhör/Referens-File/Reference
97-10-31 B
267/155 34-ASB 150 02 Uen
FACILITY DESCRIPTION
Faktaansvarig - Subject responsible
Capacity
Anyone with a facility category (COS) that includes
intrusion can undertake intrusion.
Limitations
Intrusion can only be effected on a party busy in
a normal two party call
None of parties in ongoing call shall possess a
category that prevents intrusion
Intruder must have facility category that includes
intrusion
There shall exist free connection paths in confer-
ence circuit.
Programming
0101
Assign facility category
An extension that is authorized to undertake intrusion
must have a facility category that includes intrusion.
xxxx Enter extension's directory number
zz Enter relevant facility category (0 - 15)
3004
Program facility category list
xx Enter facility category (0 - 15)
z Enter relevant function:
Y = Intrusion permitted.
N = Intrusion forbidden (default data)
See also CATEGORISATION,
document 149/155 34-ASB 150 02 Uen.
10 Jul 14:40 +15˚
FACILITY COS 0101 xxxx zz
backward forward c/i return
10 Jul 14:40 +15˚
INTRUSION 3004 xx z
backward forward c/i return