FACILITY DESCRIPTION
Faktaansvarig - Subject responsible
If the B-party does not have a programmed MCID
function key, he may also use a procedure to initiate
the function.
Initiate inquiry:
Press INQUIRY or LINE 2
Dial *39#
The public network answers to the inquiry by MCID
accepted or MCID rejected. The system translates
these two messages into call progress tones.
(acceptance tone and number unobtainable tone).
The inquiry call is then automatically disconnected. In
order to get back to the original call, the respective line
key has to be pressed again.
There is no display support, in conjunction with the
manual procedure.
At the end of a call
If the caller (A-party) disconnects before the "MCID-
key" was pressed or the manual procedure was
initiated, it is still possible to identify the external caller,
before going off-hook.
ISDN terminal
see user guide
CAPACITY / LIMITATION
not applicable
PROGRAMMING
System telephones
0101
Assign facility category
Extensions which should be authorized to activate the
MCID-function have to be assigned to the A-COS that
permits this function.
xxxx Enter extension´s directory number
zz Enter relevant facility category (0-15)
3079
Malicious call id
States which A-COS may execute the MCID function.
xx Enter facility category (0-15)
z Enter relevant function
Y = allowed
N = not allowed
10 Jul 14:40 +15˚
FACILITY COS 0101 xxxx zz
backward forward c/i return
10 Jul 14:40 +15˚
MALICIOUS CALL ID 3079 xx z
backward forward c/i return