FACILITY DESCRIPTION
Faktaansvarig - Subject responsible
loud-speaker will be interrupted while the (if any) group
key lamp keeps flashing until the call ends.
Capacity
Eight paging groups can be programmed.
The number of extensions per paging group is not
limited.
An extension or operator can be a member of any
number of paging groups.
Limitations
The following prerequisites apply for initiation of a
paging call:
Calls can only be made from telephones with a
key programmed for loudspeaker paging
Line 1 or Line 2 * shall be free
( * not available on BASIC Telephone)
No other paging shall be ongoing in the group
The following prerequisites apply for a paging call to be
announced via a telephone:
The telephone must have a loudspeaker
The extension must be programmed as a
member of the group
The extension must be completely free
The user cannot adjust the volume for loudspeaker
paging by means of the + - and - - keys.
It is however possible to individually program the level
for loudspeaker paging. See ”Programming” below.
Programming
0101
State which extensions are permitted to undertake
paging
xxxx Enter extension's directory number
zz Enter relevant facility category (0 - 15).
Initially, all extensions belong to group 0.
3006 - 3013
Facility category list
For programming of the facility category list, see
CATEGORISATION,
document 149/155 34-ASB 150 02 Uen.
Here it is stated, for each facility category, whether
paging is permitted in groups 0 - 7.
Commands can be set to:
Y = yes
or
N = no
Initially all commands are set to N = no.
LOUDSPEAKER
PAGING GROUP
FACILITY CATEGORY
GROUP
00 01 02 -- 15
3006 Group 0 Y Y Y -- Y
3007 Group 1 Y Y Y -- Y
||||
3013 Group 7 N N N -- N
10 Jul 14:40 +15˚
FACILITY COS 0101 xxxx zz
backward forward c/i return