User`s guide
15(32)
Datum/Date Rev
Dokumentnr/DocumentnrUppgjord/Prepared
Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Tillhör/Referens-File/Reference
99-08-17 E
340/155 34-ASB 150 02 Uen
FACILITY DESCRIPTION
Faktaansvarig - Subject responsible
If no voice channels are free for internal retrieving the
following message is shown on the display (if any) of
the caller:
EXECUTIVE Telephone
STANDARD Telephone
OPERATOR Telephone
If no voice channels are free, external retrievers or
telephone sets without a display will receive the ringing
tone until a voice channel becomes free again.
If there is no free voice channel within timeout, the
external caller will be rerouted to the reroute position of
the relevant trunk.
Number of common mailboxes in a hotel system
The number of common mailboxes in a mailbox
system is 16.
If ASB15002 is programmed as a hotel system the
number of common mailboxes is limited to 5.
The reason for this limitation is the number of possible
voice announcements !
There are 16 different voice announcements available.
When storing messages a guest will hear the greeting
announcement in his/her check-in language so 3
different voice announcements have to be
programmed for each common mailbox.
EXIT Position has activated call forwarding to the
mailbox system
If a caller was routed to the EXIT position he/she
cannot be rerouted back to the mailbox system via an
activated call diversion (direct, on busy or on no reply)
or follow-me.
If the EXIT position has activated any call forwarding to
the mailbox system, the calling party will NOT be
diverted.
Disconnection signal detection
When recording a voice message it is not necessary to
record a silence or disconnection signal.
There are four line signal schemes (6, 7, 27 and 38)
which do not have an active disconnection signal of the
A-party in the line signalling. On the analogue trunk
board the Tone Receiver Circuit (TRC) is will detect the
disconnection tone also for these line signal schemes.
When a disconnection tone is detected at the TRC, the
connection will be released.
To define the cadence of the disconnection tone three
commands (1420-1422) have to be programmed. (See
chapter "Programming" for more information)
An automatic silence detection is implemented in the
system. You may change the values according to your
own needs.
NOTE: Messages shorter than 1 second will
not be recorded.
10 Jul 14:40 +15˚
CONGESTION TRY LATER
10 Jul 14:40 +15˚
CONGESTION TRY LATER
10 Feb 14:40 +15˚
CONGESTION TRY LATER
C= 0 I= 0