User`s guide
44(59)
Datum/Date Rev
Dokumentnr/DocumentnrUppgjord/Prepared
Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Tillhör/Referens-File/Reference
99-07-15 A
365/155 34-ASB 150 02 Uen
FACILITY DESCRIPTION
Faktaansvarig - Subject responsible
1918
Connected line presentation on
The command is used to define whether an ASB-
party's line directory number may be sent to the
network.
Valid data: Yes/No
No
Connected ASB-party's directory
number is not sent to the network
Ye s
Connected ASB-party's directory
number is sent to the network
Default data: No
1919
TEI value
NOTE:This command is only applicable for the
T-interface. (BTU-B / MFU)
The command is used to assign a TEI (Terminal
Endpoint Identifier) value to the basic access
ISDN-link (Q- / T-interface). This command is used if a
non-automatic assignment is be used, i. e. a
programmed TEI value. If automatic assignment is
used, which means that the TEI value will be received
from the network on request, no programming shall be
done. The 'undefined' TEI value will inform the trunk to
make a request to the network.
Valid data: FF,00-63h
FFh
automatic TEI value
00-63
valid by assigned TEI Valid data
Default data:(T): FFh = undefined, see above
(Q): 00
This command is only programmable for T-interface,
for the Q-Interface there always a fixed definition.
1920
CRC4 check
NOTE:This command is only applicable for the
T-interface.
The command is used to define the mode of the Cyclic
Redundancy Check (CRC4) for ISDN Primary Rate
Access (PRA). CRC-4 procedure for multiframe
alignment and bit error monitoring is designed to
supervise whether frame alignment has been lost and
whether the bit error rate is within a specified range.
There are two modes of operation:
Automatic The equipment adapts to the
operation of the network.
This will mode be used in most
markets.
Permanently This mode is used if the network
does not support the automatic
function.
Valid data: 0-3
0 Automatic selection
(by layer 1)
1 CRC4 procedure
permanently enabled
2 CRC4 procedure
permanently disabled
3 Default
(use market-dependent
parameter)
Default data: 0
1921
Ignore inband info at disconnection
This command states whether inband information, if it
is available after DISCONNECT, shall be ignored and
immediate call clearing shall be initiated or whether the
inband information shall be transmitted to the user.
Valid data: Yes/No
No
Inband information is not ignored
(the user receives the inband
information).
Ye s
Inband information is ignored
(the call is immediately released).
Default data: Yes
NOTE:If MCID is subscribed, this command is not
relevant any more.