User`s guide
2(3)
Datum/Date Rev
Dokumentnr/DocumentnrUppgjord/Prepared
Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Tillhör/Referens-File/Reference
98-01-27 B
362/155 34-ASB 150 02 Uen
FACILITY DESCRIPTION
Faktaansvarig - Subject responsible
Capacity
For night service each trunk can be assigned an
individual answering position and a divertee answering
position.
The trunks can be divided in up to eight groups with an
optional number of members per group.
Limitations
Night service can be activated only by the or those
extensions that possess a facility category which
includes night service.
Programming
Programming of answering positions
Each trunk is to be assigned both an individual
answering position and alternative answering position
for night service.
1102
Individual answering position night
xxxx Enter trunk's directory number
zzzz Enter answering position's directory
number
1104
Alternative answering position night
To be programmed as individual answering position.
See above.
1019
Night switching trunk group
It can be stated for every trunk line to which night
service connection group it belongs.
Authorisation for night switching
Authorisation to night switch the system or individual
groups is determined by the extension's facility
category. In respect of the night switching, the
following commands are affected:
3001
Day/night initiation
Gives general permission to night switch via
command *8#.