User`s guide
2(2)
Datum/Date Rev
Dokumentnr/DocumentnrUppgjord/Prepared
Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Tillhör/Referens-File/Reference
97-10-31 C
382/155 34-ASB 150 02 Uen
FACILITY DESCRIPTION
Faktaansvarig - Subject responsible
Capacity
An Analogue telephone has only one call possibility.
A System telephone has three different call
possibilities: Line 1, Line 2 * and Inquiry key.
( * Not available on the BASIC Telephone )
Limitations
An extension with Line 1, Line 2 and Inquiry can
initiate outgoing calls even if an incoming call has been
signalled via another traffic function.
Line 2 can be used for outgoing calls even if it is
blocked for incoming calls.
Programming
2028
Ring time internal calls
This command defines the time needed for sending a
Ringing Signal to an extension in case of an internal
call.
Valid values for this command are 0-255.
With 0, no supervision is active.
All other values state the ringing time in seconds.
If a call is diverted because of an unanswered call the
stipulated time is reseted and the supervision
restarted.
2030
Disconnect tone digital extension
If the other party goes on-hook, an analogue extension
always receives a disconnection tone (max 8 sec), for
a digital extension (with L1,L2 and Inquiry) the
disconnection tone is optional.
No: Extension disconnected directly without
any tone.
Yes: Extension disconnected with tone
(max 8 sec).
2027
Inactivity tone time
If you do not dial fast enough (within 8 seconds), the
call will be disconnected and you will hear a tone
message (TONE.INACT). The duration of this tone is
determined by this command.
The time is programmable because of different market
requirements
Note that this time is used at normal dialling only.
If you are disconnected by a service (e.g. information),
the time that has been specified by the service will be
used, normally 8 seconds.
Value: 1 - 255 seconds
If a special inactivity tone is sent, the time for that tone
can be programmed.
Equipment