User`s guide
2(2)
Datum/Date Rev
Dokumentnr/DocumentnrUppgjord/Prepared
Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Tillhör/Referens-File/Reference
97-10-31 A
445/155 34-ASB 150 02 Uen
FACILITY DESCRIPTION
Faktaansvarig - Subject responsible
0180
TCD suffix dialling COS - night
This command states to which Trunk Call
Discrimination table for suffix dialling during register
recall to PSTN to which the extension belongs to when
the exchange is night-switched.
The trunk number category controls which numbers
the extension can dial.
See also command 0104 for more information.
These commands are only accessible via RASC:
1417
Length of external inquiry signal
The length of the break in the loop that is sent to the
superior system can be altered.
Initial data = 011.
2088
TCD suffix dialling at authority COS - day
This command states to which Trunk Call
Discrimination table for suffix dialling during register
recall to PSTN to which the extension belongs to when
the exchange is day - switched and the authority code
is activated.
The trunk number category controls which numbers
the extension can dial. See commands 0103 and 2020
for more information.
2089
TCD suffix dialling at authority COS - night
This command states to which Trunk Call
Discrimination table for suffix dialling during register
recall to PSTN to which the extension belongs to when
the exchange is night - switched and the authority
code is activated.
The trunk number category controls which numbers
the extension can dial. See commands 0104 and 2021
for more information.
Equipment
System Telephone.
A FECU must be connected to the CPU-D4.