User`s guide
3(4)
Datum/Date Rev
Dokumentnr/DocumentnrUppgjord/Prepared
Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Tillhör/Referens-File/Reference
99-07-15 C
442/155 34-ASB 150 02 Uen
FACILITY DESCRIPTION
Faktaansvarig - Subject responsible
Programming
0101
Permitted to order reminder
Those extensions that are to be permitted to order
reminders are to be assigned a facility category (COS)
where the reminder service facility is open.
xxxx Enter extension's directory number
zz Enter relevant facility category (01 - 15)
3069
Program category list
xx Enter facility category 0 - 15
y Enter:
Y = reminder may be ordered.
N = reminder not allowed (default data)
Programming of reminder ring signal
The following functions can be set for reminder
ringing.
8301
Ring time
States the permitted duration (number of seconds) for
each reminder attempt.
zz Enter number of seconds (1 - 59).
Default data = 30
8302
Time that shall pass between two reminder
attempts
z Enter number of minutes (1 - 5).
Default data = 3
8303
Number of reminder attempts
Here is stated the permitted number of reminder
attempts before the reminder is erased.
z Enter number of reminder attempts (1 - 5).
Default data = 3
10 Jul 14:40 +15˚
FACILITY COS 0101 xxxx zz
backward forward c/i return
10 Jul 14:40 +15˚
REMINDER ORDERING 3069 xx y
backward forward c/i return
10 Jul 14:40 +15˚
REMINDER RING TIME 8301 zz
backward forward c/i return
10 Jul 14:40 +15˚
REMINDER PAUSE TIME 8302 z
backward forward c/i return
10 Jul 14:40 +15˚
REMINDER ATTEMPTS 8303 z