User`s guide
2(3)
Datum/Date Rev
Dokumentnr/DocumentnrUppgjord/Prepared
Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Tillhör/Referens-File/Reference
97-10-31 C
482/155 34-ASB 150 02 Uen
FACILITY DESCRIPTION
Faktaansvarig - Subject responsible
Facilities
By means of programming the facility category list and
assigning facility categories to the various tenants
each tenant can gain access to the desired number of
facilities.
Background music
Tenants can be assigned an individual music channel,
however the maximum is three channels.
Loudspeaker paging
Up to eight different paging groups can be
programmed so that each tenant then has its own
group.
Night service
Each tenant can switch its own trunks for night service
by a command.
It is however always possible, via one key, to switch the
entire PBX for night service.
Call Metering
By connecting a peripheral postprocessing unit,
detailed information can be obtained for each tenant
that is a member of the PBX.
Operation
See description of respective facility,
document xxx/155 34-ASB 150 02 Uen.
Capacity
A maximum of sixteen tenants can share one system.
This number can be smaller dependent on the
configuration.
See "Limitations" below.
Limitations
The number of tenants that can share one system is
dependent on the prerequisites stipulated for traffic
control and facilities.
Traffic control
The maximum number of tenant groups in the system
is 16.
The maximum number of traffic groups in the system
is 8.
For example, if each tenant is to have its own trunks
but nevertheless allow traffic between extensions, only
eight tenants can be permitted, as extension group
and trunk line groups must be assigned different traffic
group categories.
Abbreviated number dialling - common numbers
The common external abbreviated numbers can be
shared among a maximum of four tenants.
Trunk Call Discrimination
The number of accessible directions is 100.
If the PBX is divided into the maximum number of
groups (eight), all extensions in one tenant must be
subjected to the same restrictions.
OPERATORs
If the tenants are to have their own OPERATOR
Consoles, it is necessary to state the console's
individual directory number as answering position for
trunks.This means that there will be no common queue
to the OPERATORs.