User`s guide

3(10)
Datum/Date Rev
Dokumentnr/DocumentnrUppgjord/Prepared
Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Tillhör/Referens-File/Reference
97-10-31 D
486/155 34-ASB 150 02 Uen
FACILITY DESCRIPTION
Faktaansvarig - Subject responsible
5607
Assign all trunk lines a new number series
1601 - 1613 Transmission parameters:
The following commands can be set for both analogue
and digital trunks
1601
CEPT-DTMF tone receiver level (dBm0)
Detection level for the DTMF-tone receiver
1602
ETOE-DTMF tone reveiver level (dBm0)
Detection level for DTMF-tone receiver at DISA-trunk.
1603
Dial tone receiver level (dBm0).
1604
MFC-tone receiver level (dBm0)
1605
MFC tone sending level (dBm0).
1612
Transmission group 0 - 7
Each analogue trunkline can also be programmed for
the following parameters:
1606
Disconn. tone receiver level (dBm0)
1607
Call meter type
Type of call metering receiver 12/16kHz
1608
Call meter receiver level
1609
Impedance adaptation
1610
Relative sending level(dBr)
1611
Relative receiving level(dBr)
1613
Relative transmission level for DTMF
1001-1008 Trunk categories:
See also CATEGORISATION,
document 149/155 34-ASB 150 02 Uen.
Whether the categories of the trunk lines shall be
altered from initial (default) data is stated below:
1001
Facility COS
Initial data = 0
1002
Traffic group
Initial data = 0
1003
TCD day COS
Initial data = 0
1004
TCD night COS
Initial data = 0