User`s guide

7(10)
Datum/Date Rev
Dokumentnr/DocumentnrUppgjord/Prepared
Dokansv/Godkänd - Doc respons/Approved Kontr/Checked Tillhör/Referens-File/Reference
97-10-31 D
486/155 34-ASB 150 02 Uen
FACILITY DESCRIPTION
Faktaansvarig - Subject responsible
1409
Time for recall on transfer before answer
States time before the call that was transferred before
answer recalls that initiated the party transfer.
Initial data = 60s
1410
Time for recall on camp on
States time before a camped on call recalls the party
that initiated the camp on.
Initial data = 60s
1414 - 1416 Detection and blocking times
For these commands it is possible to set the desired
time. If the tine is set at 0 (initial data) the programmed
signal table will apply.
1414
Length detection 1:st PTS
Detection time for 1st dial tone. Initial data= 08
1415
Lenght detection 2:nd PTS
Detection time for 2nd dial tone. Initial data= 08
1416
Blocking time for outgoing call after disconnection.
Initial data=01
Time for outgoing traffic after terminated incoming call.
1419
Minimum supervision time between ringsignals
Time between ringsignals for disconnection of
ananswered calls.
Several routes
1015
Pre-digits for TCD and LCR
Here are stated a number of predigits where several
routes have number series with identical numbers
Initial data = 0
See also TRUNK CALL DISCRIMINATION,
document 487/155 34-ASB 150 02 Uen.
All incoming traffic
1101 - 1104 Answer positions
See also
ANSWER POSITION(S) FOR TRUNKS,
112/155 34-ASB 150 02 Uen.
1101 - 1104
Programming of answering positions
On system start all trunks are directed to directory
number 200.
Four different answering positions can be programmed
for each trunk:
Answering position, day = 1101
Answering position, night = 1102
Alternative answering position, day = 1103
Alternative answering position, night = 1104
A call is directed to an alternative answering position
when the normal answering position does not answer
within a predetermined time
xxxx Enter directory number of relevant trunk
10 Jul 14:40 +15˚
ANSWERING POS DAY 1101 xxxx zzzz
backward forward c/i return