FACILITY DESCRIPTION
Faktaansvarig - Subject responsible
zzzz Enter directory number of relevant
answering position.
Default data = 200
Step to commands 1102 - 1104 and repeat above
procedure.
1109
Common voice announcement interruptable
This command states weather the alerting on the
answering/reroute position shall start at the same time
as the common trunk announcement or not.
valid data NO Common announcement is not
interruptable (default data)
YES Common announcement is
interruptable
NOTE: If this command is set to YES and the
called party answers the call, the
common voice announcement will be
interrupted:
Direct indialling
DID using MFC-R2
1301
Incoming digit transmission
= 2 (MFC/MFE)
1312
MFC-signal scheme.
1023
Trunk line type
Select 1.
1309
PTS signal to PE = dial tone
Dial tone to superior exchange
Whether dial tone shall serve as PTS-signal for
incoming traffic is stated here.
Initial data = YES
1311
Number of digits before EOS-signal
States that a fixed number of digits shall be received
before the EOS- signal is sent to the superior
exchange.
DID-SimplifiedDISA-type
1024
Simplified DISA at day
Indialling when the system is in day mode
1025
Simplified DISA at night
Indialling when the system is in night mode
1009 - 1017 Diversions
Programmed only for direct indialling and concerns
whether calls shall be diverted in the following
circumstances.
1009
Rero on answer pos barred?
The number is barred
1010
Rero on answ pos blocked ?
The number is blocked