FACILITY DESCRIPTION
Faktaansvarig - Subject responsible
Capacity
For the VMU-HD or VMU-D board storage capacity
see “Printed Board Assemblies” chapter in SYSTEM
OVERVIEW.
VMU-HD offers up to 64 trunk voice references and
VMU-D offers up to 32.
See also under CAPACITY-paragraph of the Facility
description VOICE MESSAGE,
document 522/155 34-ASB 150 02 Uen.
Limitations
In systems equipped with VMU-D or VMU-HD the
number of simultaneous calls served by voice
functions depends on the number of VMU-D / VMU-
HD channels.
See also under LIMITATIONS-paragraph of the Facility
description VOICE MESSAGE,
document 522/155 34-ASB 150 02 Uen.
Programming
1105
Common voice announcement at day
This command is used to specify the reference number
of the common voice announcement at day time.
1106
Common voice announcement at night
This command is used to specify the reference number
of the common voice announcement at night.
1107
Busy voice announcement at day
This command is used to specify the reference number
of the busy voice announcement at day time.
1108
Busy voice announcement at night
This command is used to specify the reference number
of the busy voice announcement at night.
1109
Common voice announcement interruptable
This command states whether or not the alerting on
the answering/reroute position shall start at the same
time as the common trunk announcement.
If the call is answered during simultaneous ringing and
voice announcement, the voice message is
interrupted.
Valid data: YES / NO
Default data:NO
Alerting on the answering/reroute position
starts after the common trunk
announcement has been finished.
Following command is only accessible via system