Operator`s manual

Placing A Special Call To Another Radio
1. Make sure the radio is turned ON, and the proper System has been
selected. Press the MENU button until the name SPC CALL appears
in the display. Press the GROUP/SEL + or - buttons until the desired
name appears in the display. The radio ID may be entered manually
if using the MDX System Model radio.
2. Press the PTT button and wait for the channel available tone before
talking.
3. When completed, release the PTT button and listen for any reply.
4. When your call is finished, press the CLR button or return the
microphone to the hookswitch. The previously selected Group name
appears on the display.
Receiving An Individual Call
When you receive an Individual Call (call directed only to your radio), the
display changes to one of the following displays:
1. "*INDV*"
2. "IDxxxxx", where XXXXX is the numeric ID of the calling radio
3. "ALPHA", where ALPHA is the alpha name of the calling radio
Receiving an Individual Call will also cause the BSY indicator to turn
on. After the transmission, the BSY indicator will go out. The display
will continue to show the above until the pre-defined time-out for
calling back expires. During this callback period, press the PTT
button to return the call. If the call is not returned before the time has
expired, the display will return to the Group display with a "C*" at
the left side or a "*C" at the right side of the display or P1, P2
indicators flashing. This indicates a call has been received. Pressing
CLR will cause this indicator to go out. The radio will retain the ID
in the Special Call list until the radio is powered off or another call is
received.
GROUP SCAN OPERATION
You may program your radio to scan a number of Groups for activity.
28