4. Proceed with the Personality programming as described
in TQ-3357.
5. After saving the personality and downloading it into the
GETC, perform an operational checkout of the GETC.
OPERATIONAL CHECKOUT
Verify that the GETC is operating correctly by
performing the following steps:
1. Set the GETC dip switches S1, S2, and S3
according to the GETC's application, channel, and
frequency. Refer to SRN1060 for DIP switch
settings, Appendix A for wideband frequencies,
and Appendix B for narrow band frequencies.
NOTE
Be sure the DIP switch settings correspond to the
Personality data created.
NOTE
For MASTR III stations, set DIP switches S1-1
through S1-7 and S2-1 through S2-4 to the
CLOSED position.
2. Reset the GETC by pressing S4.
3. Complete the verification process for the specific
GETC application, by using the procedure for:
a. A Fully Trunked System
b. A Failsoft System
c. Satellite Site Receiver
Fully Trunked System
Perform the following steps to complete the operational
checkout of a trunked GETC channel moved to the Channel
Test during the Firmware Installation.
1. Verify correct LED indicators for the Trunked
System Control Channel and the idle Working
Channels as shown Table 4.
Table 4 - LED Indicators for Trunked Idle Channels
LED Indicators L1 L2 L3 L4 L5 L6 L7
Fully Trunked Idle WB
Working Channel
❍❍❍❍❍❍
Fully Trunked Idle NB
Working Channel
❍❍❍❍❍
Fully Trunked WB
Control Channel
❍❍❍❍❍
Fully Trunked NB
Control Channel
❍❍❍❍
Legend:
= OFF
= ON
= FLASHING
2. Place test calls from radios in Channel Test by
keying one of the test radios and monitoring the
audio from the other radio. Place Clear Voice calls
and if programmed, Digital Voice calls.
3. Verify LED indicators are correct, as shown in
Table 5, for the trunked channels assigned Clear
Voice and Digital Voice calls.
Table 5 - LED Indicators for Trunked Assigned
Channels
LED Indicators L1 L2 L3 L4 L5 L6 L7
Fully Trunked Assigned
WB Clear Call
❍❍❍❍❍
Fully Trunked Assigned
WB Digital Voice Call
❍❍❍❍❍
Fully Trunked Assigned
NB Clear Call
❍❍❍❍
Legend:
= OFF
= ON
= FLASHING
4. Using the System Manager, put channel back into
service by taking it out of Channel Test.
5. Repeat for all channels.
Failsoft System
Perform the following steps to verify operation of a
GETC used in a Failsoft System:
NOTE
NOTE