Remote Starter User Manual

CONFIGURATION LBI-38988
Rev. B 19
Satellite Receivers & Simulcast Remote TX
Perform the following steps when installing the
software in a GETC connected in a Voted system as a
Satellite Site Receiver or at the Remote TX Site.
NOTE
For Voted systems using Satellite Site Receiver
software, the Satellite Site Receiver software must
be the same version as the Main/Control Site
software before the channel will operate properly.
NOTE
For Simulcast systems, all Satellite Receivers of a
channel must use the same software version, and
the receiver software need not be the same as the
Control Point software although it is
recommended.
We also recommend upgrading the Satellite Site
Receiver software before the Main/Control Site.
Receiver sites are somewhat redundant in their
operation, and changing one site has only a
localized affect on the over all operation.
1. Power down the channel and place the GETC into
the service position. Refer to LBI-38894 if
necessary.
2. If upgrading from 19A149256G21 (or earlier)
software, remove RAM chip U3 and install Turbo
Board. Refer to LBI-38822 for instructions.
3. Ensure Modem chips U4 and U19 are TI AMPS
modems 19A704272P4. TI Amps modems are
required when upgrading to 349A9607G4 (or
later), replace if necessary.
4. Ensure microprocessor U1 is the “Speedy”
microprocessor 80C320 (RYT 121 6060/A). This
processor is required when upgrading the software
to 349A9607G4 (or later). Processor is available
in Speedy Upgrade Kit SPK9505. Replace if
necessary. Refer to LBI-38894 for installation
instructions.
5. Ensure Turbo Board harness has Ferrite Toroid
installed. Toroid is included in the SPK9505
Speedy Upgrade Kit. Replace if necessary. Refer
to LBI-38822 for installation instructions.
6. Remove the old EPROM (U2) from the GETC
Logic Board.
7. Install the new EPROM into the XU2 socket,
being sure to properly orient the chip.
8. Remove EEPROM U35, if necessary, from the
Logic Board. The GETC personality will reside in
the Turbo Board and this device is no longer
required.
9. Power up the channel.
10. Place the Turbo processors U1 and U2 in the
program mode by switching Turbo Board switches
S2 and S3 toward the front of the Turbo Board.
11. Download the Turbo Board Software from the disk
provided in the Turbo Media Kit, 344A4414.
Refer the Turbo Board Software Installation
section, SRN1060, SRN1062, and LBI-38822.
12. After downloading the Turbo Board software,
move switches S2 and S3 toward the back of the
Turbo Board and press the GETC Logic Board
Reset button, S4.
13. The two LEDs on the Turbo Board should light.
14. Program the GETC’s personality using the
Personality Programming procedures contained in
this manual and the detailed instructions contained
in TQ-3357 and SRN1060.
15. Perform an operational checkout using the
Satellite Receiver checkout procedures.
Single Channel Autonomous Trunking (SCAT)
Detailed SCAT Installation Instructions for Station
GETCs are available in LBI-38987. This manual also
includes complete configuration instructions.
Voted Digital Interconnect (VDI)
Detailed VDI Installation Instructions for Station
GETCs are available in LBI-39187. This manual also
includes complete configuration instructions.
NOTE
NOTE