Installation guide

iPECS eMG80
System DECT Installation Guide Issue 1.0
9
3.2.3 General Procedure for CRS
After getting well-acquainted with the operation of GDC-600TBE, and how the Base Stations
work as applicable to your facility, the CRS can be conducted
. Section 3.2.2, Preliminary
Positions of Base Stations should already have been completed.
To conduct a CRS:
1. First, verify that other DECT Base Stations in the area are powered OFF; only the one
you are working with currently should be ON.
2. Mount the GDC-600TBE at the determined temporary position as high as possible; it is
recommended to place the GDC-600TBE at higher than 2 meters.
3. Check the Received Signal Strength Indicator (RSSI) level in the GDC-450H/GDC-
500H by walking around the area; decide the cell-coverage range temporarily using the
pre-determined RSSI level.
4. Repeat CRS procedure from Step 1 at the next tentative Base Station position; it is
likely and recommended that the cell-coverage will overlap a bit as shown:
Figure 3.2.3-1 Cell Boundary Map with Base 1 and Base 2