Quality HVAC Controls Erie Valves, actuators, thermostats and controllers Make the most of your energy
PopTop™ Erie Family of Products Poptop™ Zone Valves • 1/2”, 3/4”, 1” and 1-1/4” Sweat, NPT and Inverted Flare Union. • Two-position (on/off), 2-way and 3-way. • General close-off or High close-off. Erie’s motorized hydronic valves, the PopTop™, provide convenient, reliable and easy installation for a variety of heating and cooling applications. Installation is a snap with easy, one-handed removal or engagement of the actuator to the valve body. Push the button and lift. It’s that simple.
PopTop™ 2-Position Zone Valves Erie’s line of motorized hydronic valves, the PopTop, provides convenient, reliable, and easy installation for a variety of heating and cooling applications. The PopTop makes installation a snap with easy, one-handed removal or engagement of the actuator to the valve body.
PopTop™ 2-Position Actuators The following tables contain a complete listing of Erie 2-Position actuator combinations for 24 and 120 Vac. The same combinations are available for 208 Vac (D designator) and 230 Vac (U designator). The end switch option, (designated by the A at the end of the part #) is not available in the combination of 277 Vac with high temperature. Features Features • Sized to fit most baseboard applications. • Terminal block option.
PopTop™ 2-Position Zone Valve Assemblies 2-way normally open and additional combinations are also available, see bulletin F-26496. Features Features • Factory assembled valve and actuator combinations. • Offers the same great features as the General Close-Off assemblies, plus up to 25% more close-off psi.
Part Numbering System Two Position Zone Valves, Spring Return Actuators V X X X X X X X X X XX X 1 2 Options Body Type T = On/Off General S = On/Off Steam* * High temperature actuator must be used. 0 = No options A = End switch Voltage Valve Size 2 = 1/2” 3 = 3/4” 4 = 1” 5 = 1-1/4” Connection Type (Availability) 1 = Sweat (1/2”, 3/4”, 1”, 1-1/4”) 2 = Threaded NPT (1/2”, 3/4”, 1”) 3 = Threaded Rp, Metric (1/2”, 3/4”, 1”) 4 = Inverted flare (1/2”) 3 5 = SAE flare (1/2”) 1 = 1.0 1.5 2 = 2.
PopTop™ Modulating Valves and Actuators Erie offers a modern, cost effective range of electrically operated, modulating, temperature control valves and actuators available from any supplier. These highly reliable valves are designed specifically for use in fan coil, VAV reheat, unit ventilator, AHU, baseboard, and radiant applications. The compact design installs in small end compartments and still allows service access. Designed for use in closed hydronic heating and cooling applications.
PopTop™ Modulating Non-Spring Return Valve Assemblies Features Features • Quicker installation time • Offers the same great features as the three-wire floating assemblies • Easier maintenance • Operating range of 0 to 10 Vdc or 4 to 20 mA proportional control • Compatible with most DDC systems • UL listed • Jumper selectable operating ranges • UL Listed Three-wire Floating, 24 VAC Modulating, non-spring return 2-way Three-wire Floating Proportional, 24 VAC 0 to 10 VDC, or 4 to 20 mA, non-spr
PopTop™ Modulating Spring Return Valve Assemblies Spring return actuators return to the normal position when the power is lost for more than two seconds.
Part Numbering System Two Position Zone Valves, Spring Return Actuators 1 V M X X X X X X 3 A 00 X 2 Body Type Options M = Modulating Non-Spring Return Actuators 0 = No options T = 3-wire signal time-out Spring Return Actuators 3 T = Time-out Configuration 2 = 2-way 3 = 3-way Valve Size 2 = 1/2” 3 = 3/4” 4 = 1” 5 = 1-1/4” Electrical Leads 00 = No leads Connection Type (Availability) 1= Sweat (1/2”, 3/4”, 1”, 1-1/4”) 2= Threaded NPT (1/2”, 3/4”, 1”) 3= Threaded Rp, Metric (1/2”, 3/4”, 1”) 5= SA
Erie Damper Actuators Damper Actuators provide control for forced air zoning and draft control of solid fuel boilers and furnaces. The exclusive lost-motion drive protects the gear train from damage.
Boiler Boss Featuring the ZoneTrak™ Window and Priority Plus Boiler Boss Relays Boiler Boss relays are the most advanced and reliable single and multiple zone switching relays on the market today. Simplified wiring and universal compatibility makes installation clear.
Injection Pump and Valve Mixing Controls Injection pump mixing control Valve mixing control The system 3000 injection Pump Mixing Control with reset The System 3600 3-way Mixing Valve Control with reset provides control of the water temperature in the secondary provides control of the water temperature in the secondary (radiant) loop of a heating system, based on outdoor air (radiant) loop of a heating system.
Thermostats, Non-Digital Erie offers advanced design in electronic microprocessor based thermostats and controllers. Erie combines the simplicity of a thermostat with the versatility and power of a controller. Ease of installation is combined with the flexibility of applications and maximum compatibility. Proportional plus integral (PI) control algorithms with advanced adaptive logic guides the microprocessor based units.
Thermostats, Digital Microprocessor Thermostats, Digital Display, Controller, 3-wire Floating, and On/Off Microprocessor Thermostats, Digital Display, Controller, 0-10 Vdc or 4-20 mA The T168 thermostats provide digital control of fan coil units, air handling units, and terminal units and feature an LCD. Features The T158 thermostats provide microprocessor control of fan • LCD display coil units, air handling units, and terminal units and feature • 0-10 Vdc or 4-20 mA outputs an LCD.
© 2006-2012 Schneider Electric. All rights reserved. Schneider Electric 1354 Clifford Avenue Loves Park, IL 61111 Phone: + 1 888 444 1311 www.schneider-electric.com/buildings F-27085-7 On October 1st, 2009, TAC became the Buildings Business of its parent company Schneider Electric. This document reflects the visual identity of Schneider Electric, however there remains references to TAC as a corporate brand in the body copy.