Product Manual A
Table Of Contents
3 TECHNICAL DATA
0463 709 101
- 12 -
© ESAB AB 2020
3 TECHNICAL DATA
Technical data
Rogue ES 130i PRO
(0700500091)
Rogue ES 180i PRO
(0700500070)
Outlet voltage 120V±15%
1~ 50/60Hz
230V±15%
1~ 50/60Hz
120V±15%
1~ 50/60Hz
230V±15%
1~ 50/60Hz
Primary current
I
max
Stick
21 A 17 A 25.7A 26A
I
max
LiveTIG
20 A 10 A 23A 16.5A
No-loadpower
demand when in
energy-saving
mode 50 W 50 W 50W 50W
Setting range
Stick 20–90 A 20–130 A 20–110A 20–180A
Live TIG 10–130 A 10–130 A 10–140A 10–180A
Permissible load at Stick
25% duty cycle 90 A/23.6 V 130 A/25.2 V 110A/24.4V 180A/27.2V
60% duty cycle 58 A/22.3 V 84 A/23.4 V 70A/22.8V 116A/24.6V
100% duty cycle 45 A/21.8 V 65 A/22.6 V 55A/22.2V 90A/23.6V
Permissible load at Live TIG
25% duty cycle 130 A/15.2 V 130 A/15.2 V 140A/15.6V 180A/17.2V
60% duty cycle 84 A/13.4 V 84 A/13.4 V 90A/13.6V 116A/14.6V
100% duty cycle 65 A/12.6 V 65 A/12.6 V 70A/12.8V 90A/13.6V
Apparent power I
2
at maximum
current 2.5 kVA 2.2 kVA 3.2kVA 6kVA
Active
power I
2
at maximum
current 2.47 kW 2.17 kW 3.17kW 5.94kW
Power factor at maximum current
Live TIG 0.99 0.99 0.99 0.99
Stick 0.99 0.99 0.99 0.99
Efficiency at maximum current
Stick 84% 84% 85% 82%
Live TIG 84% 84% 85% 82%
Open-circuit voltage U
0
max
VRD 35 V
deactivated 78V 78V
VRD 35 V activated <30V <30V