Product Manual A

4 INSTALLATION
0463 709 101
- 15 -
© ESAB AB 2020
4.3 Main supply
The power source will automatically adjust to the supplied input voltage. Make sure that it is
protected by the correct fuse rating. A protective ground connection must be made, in
accordance with regulations.
1.
Rating plate with supply connection
data.
Recommended fuse sizes and minimum cable area for Rogue ES 130i PRO
Power cable for heavy-duty applications (SOOW type) must be used
Supply voltage 230VAC 120VAC
Electrical cable area 14 AWG (2.0mm
2
) 14 AWG (2.0mm
2
)
Maximal current rating I
max
Stick (SMAW) 17A 21A
I1eff Stick (SMAW) 8.5A 10.5A
Fuse anti-surge type D MCB 16A 16A
Recommended fuse sizes and minimum cable area for Rogue ES 180i PRO
Power cable for heavy-duty applications (SOOW type) must be used
Supply voltage 230VAC 120VAC
Electrical cable area 14 AWG (2.0mm
2
) 14 AWG (2.0mm
2
)