Instruction manual

- 20 -
bh32d1aa
5.2.1 Recommended fuse sizes and minimum cable area
Arc 151i Arc 201i
Mains voltage
230 V 10 %, 1-phase 230 V 10 %, 1-phase
Mains frequency 50-60 Hz 50-60 Hz
Mains cable, area 3G2.5 mm
2
3G2.5 mm
2
Phase current I
1eff
11.5 A 13.4 A
Welding cable, area 16 mm
2
16 mm
2
Fuse
anti-surge
type C MCB
16 A
13 A
16 A
16 A
NOTE!
The cable area and fuse rating above comply with Swedish regulations. Use the
welding power source in accordance with the relevant national regulations.
6 OPERATION
General safety regulations for the handling of the equipment can be found on
page 3. Read through before you start using the equipment!
BEFORE MAKING ANY CONNECTIONS TO THE POWER SOURCE OUTPUT
TERMINALS, MAKE SURE THAT ALL PRIMARY INPUT POWER TO THE MACHINE
IS OFF.
ELECTRIC SHOCK CAN KILL! “MACHINERY LOCKOUT PROCEDURES” SHOULD BE
EMPLOYED. IF IT IS NOT POSSIBLE TO USED PADLOCKS, ATTACH A RED TAG TO
THE LINE DISCONNECT SWITCH (OR FUSE BOX) WARNING OTHERS THAT THE
CIRCUIT IS BEING WORKED ON.
ELECTRIC SHOCK CAN KILL! WHEN THE CONTACTOR SWITCH IS IN THE “ON”
POSITION, OUTPUT POWER WILL BE PRESENT THROUGHOUT THE WELDING
CIRCUIT; IE. CABLES, WIRE FEEDER, WIRE SPOOL, DRIVE STAND, GUN AND
ELECTRODE. BE SURE ALL ARE CLEAR OF THE WORKPIECE OR ARCING WILL
RESULT.
Never operate the power source with the cover removed. In addition to the safety
hazards, improper cooling may cause damage to the components. Keep side
panels closed when unit is energized. Welding helmet, gloves and other personal
protection should always be worn when welding.
US