Instruction manual
GB
50
55..66 SSeett--uupp mmeennuu
Pressing the set-up button for 2s you access to the set-up menu confirmed by a central
"0" on the display.
Via the knob you vary the set-up line, via the set up button you confirm the required line,
via the knob you vary the parameter value, an so on.
If line "1" is confirmed with the button you return to the factory-set values.
If line "0" is confirmed with the button you quit set-up and you save the parameters you
have changed.
Here is the complete list of the set-up parameters:
NN.. WWeellddiinngg MMooddee DDeessccrriippttiioonn
0 TIG/MMA Save and exit
1 TIG/MMA Reset and return to pre-set values
2 TIG Pre-gas time (s), 0.0s-25.0s. Pre-set value = 0.1s
3 TIG Start current (% of welding current), 0% - 500%.
Pre-set value= 50%.
4 TIG Slope-up time (s), 0.0s-10.0 s. Pre-set value = 0.0s.
5 TIG The second welding current value (%of welding current) in TIG
MANUAL PULSE, 0-500%. Pre-set value = 50%.
6 TIG Final current (%of welding current), 0-500%. Pre-set value = 50%.
7 TIG Post-gas time (s). 0.0-25.0. In 0.0 you have an automatic Post-
gas time. Pre-set value = 0.0s.
8 TIG Trigger modes, 0=2T, 1=4T, 2=MANUAL PULSE. Pre-set value = 0.
10 MMA Hot-start (% added to welding current), 0-500%. Pre-set value = 80%.
11 MMA Arc-force (% added to welding current), 0-500%. Pre-set value = 30%.
CURRENT
MMMMAA WWEELLDDIINNGG
TTIIGG WWEELLDDIINNGG ((MMAANNUUAALL PPUULLSSEE))
TIME
CURRENT
TIME
Approx = 1 s
I1 = HOT START (ADJ. 0-500% OF I2 + I2)
I2 = SET CURRENT (0-150 A)
I1 = START CURRENT (ADJ. 0-500% OF I2)
I2 = SET CURRENT (0-150 A)
I3 = FINAL CURRENT (ADJ. 0-500% OF I2)
I4 = PULSE CURRENT (MANUAL PULSE)