User manual
-- 6 --
bi07d1aa
No arc force High arc force
Short hot start time Long hot start time
3.3 Settings example
Settings Value
Electrode Basic
“Hot start” ON
Hot start time 5
Arc force 5,0
Current 120 Amp
Electrod e = Basic
S Select the type of electrode by pressing the first function pushbutton until is
shown in the display.
Hot start time = 5
S Press
to turn hot starting ON.
S Press until 5,0 is shown in the display.