2 MENUS
The control panel uses several different menus. They are the main, measurement and
settings menus.
2.1 Main and measurement menus
The main menu is always displayed immediately after the
machine is started. The menu shows the values which have
been set. If the main menu is displayed when welding begins, it
switches over automatically to show the measured values
(measurement menu). The measured values will be displayed
even after welding has been completed.
The settings menu can be accessed without losing the measurement values. It is only
when the knob is turned that the setting values are displayed instead of the measured
values.
2.2 Settings menu
Different values can be entered in the settings menu.
To access the settings menu, press , , or
.
When the power source is switched off and restarted, the last values to be set are
recalled.
3GMAWELDING
3.1 Electrode
GMA welding uses a filler wire electrode wound on a carrier such as a spool, core or
MarathonPact. This type of electrode is referred to throughout this handbook as
wire.
3.2 Settings
Settings Setting range In steps of: Default setting
Process GMA, SMA or
Arc--air gouging
-- MIG
2/4--stroke* 2--stroke or 4--stroke -- 2-- stroke
Crater filling* ON or OFF -- OFF
Crater filling time 0--5s 0,1 s 1,7 s
US