CB Series Battery Powered Counting Scales Escali TM Digital Scales ELECTRONIC SCALE OPERATING MANUAL
SPECIFICATION CB Series g lb g lb E3CB 3,000 6 0.5 0.001 Operating Temp., Humidity E15CB 15,000 30 2/5 0.005/0.01 50% of Full Capacity 20~6,000 40~15,000 0.04~12 0.08~30 -10 ~ +40 , 85% g lb 10~3,000 0.02~6 Power Requirement DC 1.5V(D size) X 6EA / DC 12V, 300mA(Adapter) Power Consumption Platform Size(mm) MAX.: 0.31W 337(W) × 256(L) MODEL Capacity Resolution(e) E6CB 6,000 12 1 0.
CONTENTS 1. Introduction --------------------------------------------------------------------- 2. Installation and Details for Caution Use 3. Name of Each Part 4. Instructions classified by Power Source 5. Keypad and Display Information 6.
2. Installation and Details for Caution Use * Unless you follow the cautions properly, there may be life damage or material damage. Correct Installation Procedures z z z z z z z This instrument is intended for indoor use only. Install in areas with no influence of heat, such as direct ray of light and heater. Install away from areas with either strong magnetic force or electrical noise. Install on a flat and vibration-free platform. Install in areas with no dusts and moistures.
3. Name of Each Part N-type P-type 4. Instructions classified by Power Source 1. Adapter - - Connect the adapter (DC 12V, 300mA) with the power cord. Connect the jack to the adapter jack in the back side of scale body. Use only authorized adapter. Using a different adapter may cause a problem to the scale. When connecting adapter while the battery is in the scale, the battery power will be automatically turned off and adapter power will be charged even though the battery is in the scale. 2.
5. Keypad & Display Information KEY [ ] [ 0 ]~[ 9 ], [ • ] M] KEY NAME Preset Keys (PLU keys) Number Keys Save Key [ Unit Wt. ] [ Q’ty ] [+] =] [ Tare ] [C] [ Zero ] [ ON/OFF ] Unit weight Key Quantity Key Add Key Total Key Tare Key Delete Key Zero Key Power Key FUNCTION Inputs unit price or calls up the unit price. Inputs data. Saves unit price into a preset key. (Register 20 numbers of products.
6. Function ■ Procedures to set to Zero z Used in order to set the weight display to “0 g” when it is not set to “0 g” even though there is noting on the platform. ■ Procedures to Set up and Release the Tare: Used when scaling liquid or grain type substances that require a container. z 1. 2. 3. Cases when the container weight is not known. Place the container on the platform. Push the “Tare” key when the weighing is stable. Check the lighting of Tare. z 1. 2. 3. 4.
■ Procedures to save a Preset Key (PLU key) with a Unit weight value - Use by saving the unit weight of the frequently scaled product into the preset key. (Save up to 20 PLUs.) Make sure the display is set to “0g” before inputting unit price. WEIGHT ZERO TARE Short Q'ty Short Unit Wt. kg QUANTITY pcs UNIT WEIGHT TOTAL lb g/pc BAT 1. Input the unit weight by using the number keys. (unit weight is “2 g”) W eighing range : 40 g ~ 6/15 kg, e = d : 2 g / 5 g (0.1 lb ~ 15/30 lb, e = d : 0.005 lb/0.
■ Procedures to add up the Unit weight - Although there are many products to be measured, the quantity of the scaled each objects can be added up disregarding their unit weight. - The number of add-ups can be possible up to 99 times and the total add-up value can be possible up to 99,999.999. [ex] Cases when adding up the unit weight of the three different products (ex: unit weight 2g, 1. product A weight with 200g, 2. product B with weight 500g, 3.
WEIGHT ZERO TARE Short Q'ty Short Unit Wt. kg QUANTITY pcs UNIT WEIGHT TOTAL lb g/pc BAT 6. Remove the product B, place the product C W eighing range : 40 g ~ 6/15 kg, e = d : 2 g / 5 g (0.1 lb ~ 15/30 lb, e = d : 0.005 lb/0.01 lb) Model : CB-15N WEIGHT ZERO TARE Short Q'ty Short Unit Wt. kg QUANTITY pcs UNIT WEIGHT TOTAL lb g/pc BAT 7. Push the “+” key Model : CB-15N W eighing range : 40 g ~ 6/15 kg, e = d : 2 g / 5 g (0.1 lb ~ 15/30 lb, e = d : 0.005 lb/0.
■ Procedures to set up time to automatically turn off the power WEIGHT ZERO TARE Short Q'ty Short Unit Wt. kg QUANTITY pcs UNIT WEIGHT TOTAL lb g/pc BAT - Push the “C” key for 5 seconds while the weight, quantity, unit weight of the scale are zero state and Tare is released as the picture No. 1. Model : CB-15N W eighing range : 40 g ~ 6/15 kg, e = d : 2 g / 5 g (0.1 lb ~ 15/30 lb, e = d : 0.005 lb/0.01 lb) WEIGHT ZERO TARE Short Q'ty Short Unit Wt.
Warranty Regulations 1. 2. Warranty information and term of its validity. The scale's breakdown under normal operating condition is guaranteed for a repair with no charge for 1 year from the date of its purchase. Exception for guaranteed repair. Breakdown caused by following reasons are exceptions for guaranteed repair.