8.Exposure controls/personal protection
(a) Control parameters Exposure Guidelines
Chemical Name
ACGIH TLV
OSHA PEL
NIOSH IDLH
Lithium Cobalt Oxide
(CoLiO
2
)
12190-79-3
TWA: 0.02 mg/m3
N/A
N/A
Aluminum
7429-90-5
TWA: 1/mg/m3
respirable fraction
TWA: 15 mg/m3 total
dust TWA: 5 mg/m3
respirable fraction (vacated)
TWA: 15 mg/m3 total dust
(vacated) TWA: 5
mg/m3 respirable
TWA: 10 mg/m3
total dust
TWA: 5
mg/m3
respirable
dust
Copper
7440-50-8
TWA: 0.2 mg/m3
fume TWA: 1
mg/m3 Cu dust and mist
TWA: 0.1 mg/m3
fume TWA: 1 mg/m3
dust and mist (vacated)
TWA: 0.1 mg/m3 Cu
dust, fume, mist
IDLH: 100 mg/m3
dust, fume and mist
TWA: 1 mg/m3
dust and mist
TWA: 0.1 mg/m3 fume
Graphite
7782-42-5
TWA: 2.5 mg/m3 F
TWA: 2.5 mg/m3 F TWA: 2.5
mg/m3 dust
N/A
ACGIH TLV: American Conference of Governmental Industrial Hygienists -Threshold Limit Value;
OSHA PEL: Occupational Safety and Health Administration - Permissible Exposure Limits Immediately
Dangerous to Life or Health;
Other Exposure Guidelines: Vacated limits revoked by the Court of Appeals decision in AFL-CIO v. OSHA,
965 F.2d 962(11th Cir., 1992) See section 15 for national exposure control parameters;
(b) Appropriate engineering controls
Engineering Measures
1.Showers
2.Eyewash stations
3.Ventilation systems
(c) Individual protection measures, such as personal protective equipment
Eye/Face Protection
Not necessary under normal conditions, wear safety glasses if handling an
open or leaking battery.
Skin and body Protection
Not necessary under normal conditions, Wear protective gloves and
protective clothing such as long sleeved clothing, impervious gloves,
chemical resistant apron, and antistatic boots if handling an open or leaking
battery.
Respiratory Protection
Not necessary under normal conditions. If exposure limits are exceeded or
irritation is experienced, ventilation and evacuation may be required.
Hygiene Measures
Handle in accordance with good industrial hygiene and safety practice,
Avoid contact.