Installing the Electricity and Gas to the Appliance
C1 Power Supply:
Whilst the cavity is being created consideration should be given to appropriate location
of a standard 3 pin, EARTHED 230/240V power outlet. This must be within 1.0m of the rear
bottom left hand corner of the appliance.
IMPORTANT: Locating the power outlet
within the cavity makes the installation
very neat but the provision MUST be
made to be able to switch the power
supply o and on (electrical isolation
switch) and MUST be accessible after the
heater has been installed. This is normal-
ly done by means of a separate switch
which must be located adjacent to the
appliance as per AS/NZS 5601.1.2010.
This will allow service technicians to iso-
late the power supply before performing
service work on the appliance.
This appliance must not be located directly below a socket outlet.
This appliance will draw a maximum of 2 Amps from a 230/240V supply. No additional
power supply is required for the power ue.
An electrical wiring diagram is located underneath the electronic tray, and also in the rear
of this manual (Service section)
C2 Network Cable:
If the appliance is to be wired to a home automation system or internet router/network is
being installed then provision must be made for the network cable to get to the control
tray. A plastic plug is provided on the rear left of the appliance for a network cable to pass
through the chassis and reach the control tray. Allow enough slack in the network cable
to ensure the electronic tray can still be removed from the appliance. See Section E2 for
nal connection of the network cable.
Network cable
positions
Appliance
Mains Cord