Service manual

B
ACDEFGSERVICE
19
Notes:
1) Should the ue not extend past the apex, the top of the ue should extend at least
400mm from the roof (or 500mm in regions with heavy snow).
2) The installation of a ue into a carport is not recommended.
3) The ue terminal will get very hot when in use. Precautions should be taken to protect
people and animals from injury.
D3 Creating the Hole in the Outside Wall
When cutting the hole in the outside wall, be mindful of how the
installation Horizontal Powerue Wall Terminal will be nished, the
installation must be weatherproof.
Ideal hole/cavity size for Horizontal Powerue
Without Side Brackets With Side Brackets
X 298mm 360mm
Y 298mm 298mm
Z 175mm Excluding allowance for ue which exits here
The Horizontal Powerue Wall Terminal can be attached to the wall in two ways,
A) From the front of the terminal:
B) By attaching the optional Wall Terminal Installation Brackets to the sides of the cavity
and attaching the Horizontal Powerue Wall Terminal to these, from the front:
D4 Installing the Horizontal Powerue Wall Terminal
Attach the Ø100mm and Ø75mm exible aluminium ues to the spigots on the rear of
the Horizontal Powerue Wall Terminal using the hose band clamps supplied. Plug the
powerue electrical cable into the back of the Horizontal Powerue Wall Terminal.
For information on the PolyPro ue , see the installation manual which is supplied with
the ue components.
Ensure that the electrical cable is rmly secured to the wall terminal or building to pre-
vent damage or disconnection if pulled