D6 Installation the restrictor plate (Vertical Power Flue Only)
Every Vertical Power Flue must have the restrictor plate tted when installating a DL850
or DL1100. To do this:
Remove the powerue lid, remove the screw that secures the elbow & then slide the
elbow o.
Attach the restrictor centrally over the air
inlet as shown using the two rivets provided.
Replace the elbow, replace the screw, and
then replace and secure the lid.
D7 Running the Flue
Run the Ø100mm and Ø75mm exible aluminium hoses from the cavity to the rear of
where the Horizontal or Vertical Powerue Terminal will be installed. The ue system for
the DL850 / DL1100 is zero rated, so no spaces are required between the ue and
any timber framing. Allow enough stretch in the exible aluminium ue to allow it to be
able to protrude through the wall/ceiling to enable it to be connected to the Powerue
Terminal. The ue should be expanded at each end in order for the ue to be attached to
the re / powerue.
For information on running the PolyPro ue , see the installation manual which is supplied
with the ue components.
It is advisable to secure the exi ue at regular intervals to prevent vibration and move-
ment. Steel wire or builders strapping may be used for this purpose.
Note: The exible ue is shipped in a ‘compressed’ form. Extend it to your desired length by
stretching (up to 4m maximum per length).
D8 Running the Powerue Electrical Cable
Note: The Horizontal Powerue Wall Terminal is powered from the appliance, and must be
connected to the appliance with the supplied electrical cable only.
Run the electrical cable from the cavity where the appliance will be installed to the hole
in the outside wall. Ensure it is not draped over, or in contact with, the outer shell of the
appliance or the ues and kept clear from any other possible heat sources, sharp edges,
or moisture. Fix it appropriately and allow enough cable looped to be able to pull both
the appliance and the Horizontal Powerue Wall Terminal out from their installed posi-
tions.
END OF SECTION D
By the end of this section, you should have:
A weather-tight installed Horizontal Powerue Wall Terminal with clearance as
specied by AS/NZ5601
Reasonable access to the outside face for maintenance purposes
Flue attached to the rear of the Horizontal Powerue Wall Terminal leading back to
the appliance
The electrical cable from the Horizontal Powerue Wall Terminal attached to the
rear of the installation and run back to the appliance cavity in an electrically safe manner