Service manual

B
ACDEFGSERVICE
25
Ret the pilot bracket / Hood assembly and pilot cover plates. NOTE: Ensure the
orientation of the pilot gas ports is as shown in section E9.
Remove the aeration collars from both burners
Ret the pilot guard and then burners.
Turn the restrictor indicator to the vertical
position as shown.
Remove the regulator screw cap and screw out the
nylon adjuster screw to remove the existing spring.
Replace the spring with the blue spring
supplied in the conversion kit and reassemble the
regulator
Adjust operating pressure to 2.3kPa for DL1100
(Propane / ULPG) and the DL850 (Propane) OR
2.6kPa for DL850 (ULPG) by turning the nylon adjustor screw whilst the appliance is
running on maximum.
Adhere the Conversion label over the top of the Natural Gas data on the appliance
data plate.
Adhere the ‘Propane’ or ‘ULPG’ label over the top of the existing Natural Gas label on
the side of the appliance (if accessable).
E9 Checking the Pilot Ignition
The placement of the electrode is CRITICAL to the opera-
tion of the re. The gap is factory set but in the event that
the electrode or pilot hood have moved during installa-
tion or the re is having trouble lighting or staying lit then
below is a guide to electrode placement. Ensure no logs,
coals, stones or pieces of Crystalight have worked their way
around the pilot guard and are touching the electrode or
pilot hood.
If the appliance has diculty igniting, ensure that the pilot
hood has the correct gap for the gas to escape from using
feeler gauges.
Ensure there is not an excessive carbon build up on either
the electrode or the pilot hood. Clean them if necessary.
As shown below, check (and if necessary, set) the gap be-
tween the 3 pilot ports to 0.5mm