Service manual

B
ACDEFGSERVICE
27
Replace the glass and the three glass retainers.
Note: Improper positioning of logs may create carbon build-up and will alter the unit’s
performance. Malfunctioning due to improper log placement is not covered under war-
ranty.
E11 River Stone or Coal (Pebbles) Fuel Bed Installation
Note: There are several types of fuel bed for the DL850 and DL1100. Please check which
fuel bed you have been supplied with and follow the installation instructions for that fuel
bed carefully.
Place all the River Stones or Coals in a single layer atop the burners, covering the entire
area. Be careful to avoid letting any fall down between the pilot head, spark electrode
and pilot guard, and if possible keep the area where the pilot hood ame is directed at
the burner ports clear to aid reliable ignition.
Replace the glass and the three glass retainers.
Note: Improper positioning of Stones/Coals/Pebbles may create carbon build-up and will
alter the unit’s performance. Malfunctioning due to improper Stone/Coal/Pebble place-
ment is not covered under warranty.
E12 Crystalight Fuel Bed Installation
Note: There are several types of fuel bed for the DL850 and DL1100. Please check which
fuel bed you have been supplied with and follow the installation instructions for that fuel
bed carefully.
Place all the Crystalight pieces in a SINGLE LAYER atop the burners, covering the entire
area. Be careful to avoid letting any fall down between the pilot head, spark electrode
and pilot guard, and if possible keep the area where the pilot hood ame is directed at
the burner ports clear. Replace the glass and the three glass retainers.
Note: Improper positioning of Crystalight may create carbon build-up and will alter the
unit’s performance. Malfunctioning due to improper Crystalight placement is not covered
under warranty